Evidence map›Paper›PMID 34216259›Full record

ArticleArchives of orthopaedic and trauma surgery2022

Femorotibial alignment measured during robotic assisted knee surgery is reliable: radiologic and gait analysis.

Etienne Deroche, Alexandre Naaim, Timothy Lording, Raphael Dumas, Elvire Servien, Laurence Cheze, Sébastien Lustig, Cécile Batailler

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Etienne DerocheOrthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France. etienne.deroche@chu-lyon.fr.ORCID http://orcid.org/0000-0001-6587-7987
Alexandre NaaimUniv Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France.
Timothy LordingMelbourne Orthopaedic Group, Melbourne, Australia.
Raphael DumasUniv Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France.
Elvire ServienOrthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.
Laurence ChezeUniv Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France.
Sébastien LustigOrthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.
Cécile BataillerOrthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeFemorotibial alignment is crucial for the outcome of unicompartmental knee arthroplasty (UKA). Robotic-assisted systems are useful to increase the accuracy of alignment in UKA. However, no study has assessed if the femorotibial alignment measured by the image-free robotic system is reliable. The aim of this study was to determine whether measurement of the mechanical femorotibial axis (mFTA) in the coronal plane with handheld robotic assistance during surgery is equivalent to a static measurement on radiographs and to a dynamic measurement during walking.

methodsTwenty patients scheduled for robotic-assisted medial UKA using handheld technology were included in this prospective study. Three measurements of the frontal femorotibial axis were compared: intra-operative acquisition by computer assistance (dynamic, non-weightbearing position), radiographic measurements on long leg X-ray (static, weightbearing position), and by gait analysis during walking (dynamic, weightbearing position).

resultsThere was no significant difference in the mFTA between computer (174.4 ± 3.4°), radiological (173.9 ± 3.3°), and gait analysis (172.9 ± 5.1°) measurements (p = 0.5). There was a strong positive correlation (r = 0.6577355, p = 0.0016) between robotic-assisted measurements and gait analysis.

conclusionThere was no significant difference in the femorotibial axis measured by the image-free robotic assistance, from the preoperative radiographs or by gait analysis. The reliability of intra-operative measurements of the frontal femorotibial axis by these robotic-assisted systems is acceptable.

Indexed as

Osteoarthritis, KneeRobotic Surgical ProceduresGait AnalysisHumansKnee JointProspective StudiesReproducibility of ResultsFemorotibial alignmentGait analysisKneeKGRobotic-assisted surgeryUnicompartmental knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.