Evidence map›Paper›PMID 34216050›Full record

ArticleMagnetic resonance in medicine2021

Improved estimation of myelin water fractions with learned parameter distributions.

Yudu Li, Jiahui Xiong, Rong Guo, Yibo Zhao, Yao Li, Zhi-Pei Liang

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Accelerated 3D metabolite TMagnetic resonance in medicine · 2024
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yudu LiBeckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.ORCID 0000-0003-2061-2306
Jiahui XiongBeckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.
Rong GuoBeckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.ORCID 0000-0003-0405-3268
Yibo ZhaoBeckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.ORCID 0000-0002-0848-7808
Yao LiSchool of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.ORCID 0000-0001-8249-8989
Zhi-Pei LiangBeckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.

Funding

Breaking Spatiotemporal Barriers of MR Imaging Technologies to Study Human Brain Function and NeuroenergeticsU01EB026978 · NIBIB · UNIVERSITY OF MINNESOTA · PI CHEN, WEI, ZHU, XIAO-HONG · 2018 to 2022
$6.4M
Rapid High-Resolution 1H-MRSI for Metabolic Imaging of the BrainR21EB023413 · NIBIB · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI LIANG, ZHI-PEI · 2018 to 2019
$401k
NIBIB NIH HHS R21 EB023413NIBIB NIH HHS U01 EB026978
6 · The paper itself

Abstract

purposeTo improve estimation of myelin water fraction (MWF) in the brain from multi-echo gradient-echo imaging data.

methodsA systematic sensitivity analysis was first conducted to characterize the conventional exponential models used for MWF estimation. A new estimation method was then proposed for improved estimation of MWF from practical gradient-echo imaging data. The proposed method uses an extended signal model that includes a finite impulse response filter to compensate for practical signal variations. This new model also enables the use of prelearned parameter distributions as well as low-rank signal structures to improve parameter estimation. The resulting parameter estimation problem was solved optimally in the Bayesian sense.

resultsOur sensitivity analysis results showed that the conventional exponential models were very sensitive to measurement noise and modeling errors. Our simulation and experimental results showed that our proposed method provided a substantial improvement in reliability, reproducibility, and robustness of MWF estimates over the conventional methods. Clinical results obtained from stroke patients indicated that the proposed method, with its improved capability, could reveal the loss of myelin in lesions, demonstrating its translational potentials.

conclusionThis paper addressed the problem of robust MWF estimation from gradient-echo imaging data. A new method was proposed to provide improved MWF estimation in the presence of significant noise and modeling errors. The performance of the proposed method has been evaluated using both simulated and experimental data, showing significantly improved robustness over the existing methods. The proposed method may prove useful for quantitative myelin imaging in clinical applications.

Indexed as

Myelin SheathWaterBayes TheoremHumansMagnetic Resonance ImagingReproducibility of ResultsWaterBayesian estimationCramér-Rao lower boundmyelin water fractionperformance analysis

Identifiers

PMID34216050
PMCPMC8530830

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.