ArticleBMJ open gastroenterology2021
Impact of the National Endoscopy Database (NED) on colonoscopy withdrawal time: a tertiary centre experience.
Article in BMJ open gastroenterology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Overview of a national endoscopy database: The Trans.IT database and its impact on data registration quality.United European gastroenterology journal · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveColonoscopy withdrawal time (CWT) is a key performance indicator affecting polyp detection rate (PDR) and adenoma detection rate (ADR). However, studies have shown wide variation in CWT and ADR between different endoscopists. The National Endoscopy Database (NED) was implemented to enable quality assurance in all endoscopy units across the UK and also to reduce variation in practice. We aimed to assess whether CWT changed since the introduction of NED and whether CWT affected PDR.
methodsWe used NED to retrospectively collect data regarding CWT and PDR of 25 endoscopists who performed (n=4459 colonoscopies) in the four quarters of 2019. We then compared this data to their performance in 2016, before using NED (n=4324 colonoscopies).
resultsMean CWT increased from 7.66 min in 2016 to 9.25 min in 2019 (p=0.0001). Mean PDR in the two periods was 29.9% and 28.3% (p=0.64). 72% of endoscopists (18/25) had CWT>6 min in 2016 versus 100% (25/25) in 2019, the longer CWT in 2019 positively correlated with the PDR (r=0.50, p=0.01). Gastroenterology consultants and trainee endoscopists had longer CWT compared with colorectal surgeons both before and after using NED.
conclusionNED usage increased withdrawal times in colonoscopy. Longer withdrawal times were associated with higher PDR. A national colonoscopy audit using data from NED is required to evaluate whether wide variations in practice across endoscopy units in the UK still exist and to ensure minimum colonoscopy quality standards are achieved.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.