Evidence map›Paper›PMID 34214957›Full record

ArticleMedical image analysis2021

Geodesic density regression for correcting 4DCT pulmonary respiratory motion artifacts.

Wei Shao, Yue Pan, Oguz C Durumeric, Joseph M Reinhardt, John E Bayouth, Mirabela Rusu, Gary E Christensen

Abstract read
In one paragraph

Article in Medical image analysis, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Wei ShaoDepartment of Electrical and Computer Engineering, University of Iowa, Iowa City, IA 52242 USA; Department of Radiology, Stanford University, Stanford, CA 94305 USA. Electronic address: weishao@stanford.edu.
Yue PanDepartment of Electrical and Computer Engineering, University of Iowa, Iowa City, IA 52242 USA.
Oguz C DurumericDepartment of Mathematics, University of Iowa, Iowa City, IA 52242 USA.
Joseph M ReinhardtRoy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, IA 52242 USA.
John E BayouthDepartment of Human Oncology, University of Wisconsin - Madison, Madison, WI 53792 USA.
Mirabela RusuDepartment of Radiology, Stanford University, Stanford, CA 94305 USA. Electronic address: mirabela.rusu@stanford.edu.
Gary E ChristensenDepartment of Electrical and Computer Engineering, University of Iowa, Iowa City, IA 52242 USA; Department of Radiation Oncology, University of Iowa, Iowa City, IA 52242 USA. Electronic address: gary-christensen@uiowa.edu.

Funding

Vector Core-Core 2P30DK054759 · NIDDK · UNIVERSITY OF IOWA · PI Alejandro Antonio Pezzulo · 1998 to 2026
$30.5M
Lung Biomechanics and Disease Progression in SPIROMICSR01HL142625 · NHLBI · UNIVERSITY OF IOWA · PI REINHARDT, JOSEPH M · 2018 to 2021
$2.2M
Predicting Pulmonary Function Change to Improve Radiation Planning and OutcomeR01CA166703 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI BAYOUTH, JOHN · 2013 to 2017
$1.9M
Consistent anatomy registration for lung cancer adaptive radiation therapyR01CA166119 · NCI · WASHINGTON UNIVERSITY · PI HUGO, GEOFFREY D · 2013 to 2017
$1.5M
NCI NIH HHS R01 CA166119NCI NIH HHS R01 CA166703NHLBI NIH HHS R01 HL142625NIDDK NIH HHS P30 DK054759
6 · The paper itself

Abstract

Pulmonary respiratory motion artifacts are common in four-dimensional computed tomography (4DCT) of lungs and are caused by missing, duplicated, and misaligned image data. This paper presents a geodesic density regression (GDR) algorithm to correct motion artifacts in 4DCT by correcting artifacts in one breathing phase with artifact-free data from corresponding regions of other breathing phases. The GDR algorithm estimates an artifact-free lung template image and a smooth, dense, 4D (space plus time) vector field that deforms the template image to each breathing phase to produce an artifact-free 4DCT scan. Correspondences are estimated by accounting for the local tissue density change associated with air entering and leaving the lungs, and using binary artifact masks to exclude regions with artifacts from image regression. The artifact-free lung template image is generated by mapping the artifact-free regions of each phase volume to a common reference coordinate system using the estimated correspondences and then averaging. This procedure generates a fixed view of the lung with an improved signal-to-noise ratio. The GDR algorithm was evaluated and compared to a state-of-the-art geodesic intensity regression (GIR) algorithm using simulated CT time-series and 4DCT scans with clinically observed motion artifacts. The simulation shows that the GDR algorithm has achieved significantly more accurate Jacobian images and sharper template images, and is less sensitive to data dropout than the GIR algorithm. We also demonstrate that the GDR algorithm is more effective than the GIR algorithm for removing clinically observed motion artifacts in treatment planning 4DCT scans. Our code is freely available at https://github.com/Wei-Shao-Reg/GDR.

Indexed as

Four-Dimensional Computed TomographyLung NeoplasmsAlgorithmsArtifactsHumansLungMotionRespiration4DCTArtifact correctionGeodesic regressionImage registrationLung cancerMotion artifact

Identifiers

PMID34214957
PMCPMC8466681

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.