ArticleJournal of clinical laboratory analysis2021
The Hologic Aptima SARS-CoV-2 assay enables high ratio pooling saving reagents and improving turnaround time.
Article in Journal of clinical laboratory analysis, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 10 citations in OpenAlex.
- Taqman PACMAN: a simple molecular approach for positive rapid antigen test confirmation during periods of low prevalence.Microbiology spectrum · 2024Article
- Diagnostics and analysis of SARS-CoV-2: current status, recent advances, challenges and perspectives.Chemical science · 2023Review
- Evaluation of SARS-CoV-2 Detection Systems Using Clinical Samples and Standard Material: A Comparative Study.Diagnostics (Basel, Switzerland) · 2023Article
- Assessment of the clinical and analytical performance of the Aptima SARS-CoV-2 assay using the VALCOR protocol.Virology journal · 2023Article
- A precise review on NAATs-based diagnostic assays for COVID-19: A motion in fast POC molecular tests.European journal of clinical investigation · 2022Review
- COVID Community-Engaged Testing in Alabama: Reaching Underserved Rural Populations Through Collaboration.American journal of public health · 2022Article
- Review
- [Performance of the Procleix SARS-CoV-2 transcriptase-mediated amplification (TMA) assay for the diagnosis of COVID-19 in nasopharyngeal sample pools. Small pilot study].Revista espanola de quimioterapia : publicacion oficial de la Sociedad Espanola de Quimioterapia · 2022Article
- Article
- The Hologic Aptima SARS-CoV-2 assay enables high ratio pooling saving reagents and improving turnaround time.Journal of clinical laboratory analysis · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe Hologic Aptima™ TMA SARS-CoV-2 assay was employed to test pooled nasopharyngeal (NP) samples to evaluate the performance of pooled sample testing and characterize variables influencing results.
methodsResults on 1033 previously tested NP samples were retrieved to characterize the relative light units (RLU) of SARS-CoV-2-positive samples in the tested population. The pooling strategy of combining 10 SARS-CoV-2 samples into one pool (10/1) was used in this study. The results were compared with neat sample testing using the same Aptima™ TMA SARS-CoV-2 assay and also the CDC RT-PCR and the Cepheid SARS-CoV-2 assays.
resultsThe Aptima assay compares favorably with both CDC RT-PCR and the Cepheid SARS-CoV-2 assays. Once samples are pooled 10 to 1 as in our experiments, the resulting signal strength of the assay suffers. A divide opens between pools assembled from strong-positive versus only weak-positive samples. Pools of the former can be reliably detected with positive percent agreement (PPA) of 95.2%, while pools of the latter are frequently misclassified as negative with PPA of 40%. When the weak-positive samples with kRLU value lower than 1012 constitute 3.4% of the total sample profile, the assay PPA approaches 93.4% suggesting that 10/1 pooled sample testing by the Aptima assay is an effective screening tool for SARS-CoV-2.
conclusionPerforming pooled testing, one should monitor the weak positives with kRLU lower than 1012 or quantification cycle (Cq) value higher than 35 on an ongoing basis and adjust pooling approaches to avoid reporting false negatives.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.