ArticleJournal of synchrotron radiation2021
BL-11C Micro-MX: a high-flux microfocus macromolecular-crystallography beamline for micrometre-sized protein crystals at Pohang Light Source II.
Article in Journal of synchrotron radiation, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 28 citations in OpenAlex.
- Temperature-Dependent Thumb Domain Dynamics of Xylanase TsaGH11: Insights from Molecular Dynamics Simulations.International journal of molecular sciences · 2026Article
- Structural basis for inhibition of TcrXyn10A xylanase by nonspecific xylose binding at subsite - 2.Scientific reports · 2026Article
- Temperature-Dependent Conformational Dynamics of Substrate Entrance Loops in β-Glucosidase: Insights from Molecular Dynamics Simulations.International journal of molecular sciences · 2026Article
- Structural basis for the recognition and ubiquitylation of type-2 N-degron substrate by PRT1 plant N-recognin.Nature communications · 2025Article
- pH-Induced Conformational Change of the Chromophore of the Large Stokes Shift Fluorescent Protein tKeima.Molecules (Basel, Switzerland) · 2025Article
- Effect of crystal-to-detector distance shift on data processing in serial crystallography.PloS one · 2025Article
- Data of crystal structure of the large Stokes shift fluorescent protein tKeima.Data in brief · 2024Article
- Data of crystal structures of single-domain substrate-binding protein fromData in brief · 2024Article
- Data on the crystal structures of β-glucosidase fromData in brief · 2024Article
- VMXm - A sub-micron focus macromolecular crystallography beamline at Diamond Light Source.Journal of synchrotron radiation · 2024Article
- Structural Analysis of the Large Stokes Shift Red Fluorescent Protein tKeima.Molecules (Basel, Switzerland) · 2024Article
- Structural and bioinformatics analysis of single-domain substrate-binding protein fromBiochemistry and biophysics reports · 2024Article
- Data of the subatomic resolution structure of glucose isomerase complexed with xylitol inhibitor.Data in brief · 2024Article
- Structural mechanism of Escherichia coli cyanase.Acta crystallographica. Section D, Structural biology · 2023Article
- Cu(I)-thioether coordination complexes based on a chiral cyclic β-amino acid ligand.Communications chemistry · 2023Article
- ID23-2: an automated and high-performance microfocus beamline for macromolecular crystallography at the ESRF.Journal of synchrotron radiation · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
18 authors at 3 institutions in 2 countries.
Funding
Abstract
BL-11C, a new protein crystallography beamline, is an in-vacuum undulator-based microfocus beamline used for macromolecular crystallography at the Pohang Accelerator Laboratory and it was made available to users in June 2017. The beamline is energy tunable in the range 5.0-20 keV to support conventional single- and multi-wavelength anomalous-dispersion experiments against a wide range of heavy metals. At the standard working energy of 12.659 keV, the monochromated beam is focused to 4.1 µm (V) × 8.5 µm (H) full width at half-maximum at the sample position and the measured photon flux is 1.3 × 10
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.