ArticleJournal of synchrotron radiation2021
An ultra-high-stability four-axis ultra-high-vacuum sample manipulator.
Article in Journal of synchrotron radiation, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- The 10 m collimated Rowland spectrometer at the MAX IV Veritas beamline.Journal of synchrotron radiation · 2025Article
- A 1D imaging soft X-ray spectrometer for the small quantum systems instrument at the European XFEL.Journal of synchrotron radiation · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
A report on a four-axis ultra-high-stability manipulator developed for use at the Veritas and Species RIXS beamlines at MAX IV Laboratory, Lund, Sweden, is presented. The manipulator consists of a compact, light-weight X-Y table with a stiffened Z tower carrying a platform with a rotary seal to which a manipulator rod holding the sample can be attached. Its design parameters have been optimized to achieve high eigen-frequencies via a light-weight yet stiff construction, to absorb forces without deformations, provide a low center of gravity, and have a compact footprint without compromising access to the manipulator rod. The manipulator system can house a multitude of different, easily exchangeable, manipulator rods that can be tailor-made for specific experimental requirements without having to rebuild the entire sample positioning system. It is shown that the manipulator has its lowest eigen-frequency at 48.5 Hz and that long-term stability is in the few tens of nanometres. Position accuracy is shown to be better than 100 nm. Angular accuracy is in the 500 nrad range with a long-term stability of a few hundred nanoradians.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.