Evidence map›Paper›PMID 34212482›Full record

ArticleJournal of applied clinical medical physics2021

Evaluation of the correlation between dosimetric, geometric, and technical parameters of radiosurgery planning for multiple brain metastases.

André Vinícius de Camargo, Minsong Cao, Diego da Cunha Silveira Alves da Silva, Raphael Leonardo Cunha de Araújo

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

André Vinícius de CamargoDepartment of Radiation Oncology, Barretos Cancer Hospital, Barretos, Brazil.
Minsong CaoDepartment of Radiation Oncology, University of California, Los Angeles, CA, USA.
Diego da Cunha Silveira Alves da SilvaDepartment of Radiation Oncology, Barretos Cancer Hospital, Barretos, Brazil.
Raphael Leonardo Cunha de AraújoBarretos Cancer Hospital, Barretos, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the correlation between dosimetric, geometric, and technical parameters for radiosurgery planning of multiple brain metastasis treatments treated with a linear accelerator with volumetric modulated arc therapy (VMAT) technique. MATERIALS AND

methodsData were collected retrospectively from 55 patients who underwent radiosurgery in a single institution from August 2017 to February 2020. Patients presented 4-21 brain metastases were treated with a single fraction with doses between 18 and 20 Gy. Dosimetric variables were collected including V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, conformity index (CI), heterogeneity index (HI), maximum dose (Dmax), and the CI_R50. Geometric variables including the number of lesions, target volumes, the smallest target volume, the largest target volume, and the distance between the isocenter and the most distant lesion (DIL) and technical variables such as the numbers of total arcs, noncoplanar arcs, and isocenters were collected for analysis.

resultsThe number of lesions had a moderate positive correlation with V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, HI, Dmax, and with the number of total arcs. The target volumes had a positive medium-high correlation with V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, and moderate positive correlation with HI, Dmax, number of arcs and noncoplanar arcs. The CI and CI_R50 had a negative correlation with all volumes related to the target: the target volumes, the smallest, and the largest lesion. A positive correlation was observed between the distance of the isocenter and the most DIL with V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, HI, Dmax, and the number of isocenters.

conclusionIt was found that the number of lesions and the target volumes are good predictors of dosimetric indexes of plan evaluation and that the distance between the isocenter and the most DIL harms them.

Indexed as

Brain NeoplasmsRadiosurgeryRadiotherapy, Intensity-ModulatedHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRetrospective Studiesdosimetrics parametersgeometrics parametersmultiple brain metastasesradiosurgerytechnical parameters

Identifiers

PMID34212482
PMCPMC8364278

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.