Evidence map›Paper›PMID 34210050›Full record

ArticleBiosensors2021

Wearable Intracranial Pressure Monitoring Sensor for Infants.

Baoyue Zhang, Ziyi Huang, Huixue Song, Hyun Soo Kim, Jaewon Park

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Non-Invasive Intracranial Pressure Monitoring.Journal of clinical medicine · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Baoyue ZhangSchool of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, China.
Ziyi HuangSchool of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, China.
Huixue SongSchool of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, China.
Hyun Soo KimDepartment of Electronic Engineering, Kwangwoon University, Seoul 01897, Korea.
Jaewon ParkSchool of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, China.ORCID 0000-0002-5704-726X
Southern University of Science and Technology · CNKwangwoon University · KR

Funding

Kwangwoon University 00000Shenzhen Basic Research Grant JCYJ20180504165801830
6 · The paper itself

Abstract

Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death. Monitoring ICP can be invaluable in the management of patients suffering from brain injury or hydrocephalus. To date, invasive measurements are still the standard method for monitoring ICP; however, these methods can not only cause bleeding or infection but are also very inconvenient to use, particularly for infants. Currently, none of the non-invasive methods can provide sufficient accuracy and ease of use while allowing continuous monitoring in routine clinical use at low cost. Here, we have developed a wearable, non-invasive ICP sensor that can be used like a band-aid. For the fabrication of the ICP sensor, a novel freeze casting method was developed to encapsulate the liquid metal microstructures within thin and flexible polymers. The final thickness of the ICP sensor demonstrated is 500 µm and can be further reduced. Three different designs of ICP sensors were tested under various pressure actuation conditions as well as different temperature environments, where the measured pressure changes were stable with the largest stability coefficient of variation being only CV = 0.0206. In addition, the sensor output values showed an extremely high linear correlation (R

Indexed as

Monitoring, PhysiologicWearable Electronic DevicesBrainBrain InjuriesHumansInfantIntracranial PressurePressurefreeze castingintracranial pressure sensorliquid metalwearable sensor

Identifiers

PMID34210050
PMCPMC8301997
OpenAlexW3173306516

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.