ArticleBiosensors2021
A Novel Lightweight Wearable Soft Exosuit for Reducing the Metabolic Rate and Muscle Fatigue.
Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- A Resistive Soft Robotic Exosuit for Dynamic Body Loading in Hypogravity.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Trial
- The Impact of a Lightweight Pneumatic Robotic Knee Wearable on Gait.Case reports in orthopedics · 2026Article
- Biomechanics-Informed Mechatronics Design of Comfort-Centered Portable Hip Exoskeleton: Actuator, Wearable Interface, Controller.IEEE transactions on medical robotics and bionics · 2025Article
- [Research status of lower limb exoskeleton rehabilitation robot].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024Review
- Emerging Medical Technologies and Their Use in Bionic Repair and Human Augmentation.Bioengineering (Basel, Switzerland) · 2024Review
- A Critical Review on Factors Affecting the User Adoption of Wearable and Soft Robotics.Sensors (Basel, Switzerland) · 2023Review
- Soft Wearable Robots: Development Status and Technical Challenges.Sensors (Basel, Switzerland) · 2022Review
- Design Consideration Investigation of Soft-Valve Pipe.Micromachines · 2022Article
- A Portable Waist-Loaded Soft Exosuit for Hip Flexion Assistance with Running.Micromachines · 2022Article
- Anti-Disturbance Sliding Mode Control of a Novel Variable Stiffness Actuator for the Rehabilitation of Neurologically Disabled Patients.Frontiers in robotics and AI · 2022Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Wearable robotic devices have been proved to considerably reduce the energy expenditure of human walking. It is not only suitable for healthy people, but also for some patients who require rehabilitation exercises. However, in many cases, the weight of soft exosuits are relatively large, which makes it difficult for the assistant effect of the system to offset the metabolic consumption caused by the extra weight, and the heavy weight will make people uncomfortable. Therefore, reducing the weight of the whole system as much as possible and keeping the soft exosuit output power unchanged, may improve the comfort of users and further reduce the metabolic consumption. In this paper, we show that a novel lightweight soft exosuit which is currently the lightest among all known powered exoskeletons, which assists hip flexion. Indicated from the result of experiment, the novel lightweight soft exosuit reduces the metabolic consumption rate of wearers when walking on the treadmill at 5 km per hour by 11.52% compared with locomotion without the exosuit. Additionally, it can reduce more metabolic consumption than the hip extension assisted (HEA) and hip flexion assisted (HFA) soft exosuit which our team designed previously, which has a large weight. The muscle fatigue experiments show that using the lightweight soft exosuit can also reduce muscle fatigue by about 10.7%, 40.5% and 5.9% for rectus femoris, vastus lateralis and gastrocnemius respectively compared with locomotion without the exosuit. It is demonstrated that decreasing the weight of soft exosuit while maintaining the output almost unchanged can further reduce metabolic consumption and muscle fatigue, and appropriately improve the users' comfort.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.