Evidence map›Paper›PMID 34207961›Full record

ArticleSensors (Basel, Switzerland)2021

Validation of a New Contactless and Continuous Respiratory Rate Monitoring Device Based on Ultra-Wideband Radar Technology.

Timo Lauteslager, Michal Maslik, Fares Siddiqui, Saad Marfani, Guy D Leschziner, Adrian J Williams

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Combining a wireless radar sleep monitoring device with deep machine learning techniques to assess obstructive sleep apnea severity.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2024
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Ultra-Wideband (UWB) Systems in Biomedical Sensing.Sensors (Basel, Switzerland) · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Timo LauteslagerCircadia Technologies Ltd., 6 Delmey Close, London CR0 5QD, UK.ORCID 0000-0002-4518-0063
Michal MaslikCircadia Technologies Ltd., 6 Delmey Close, London CR0 5QD, UK.
Fares SiddiquiCircadia Technologies Ltd., 6 Delmey Close, London CR0 5QD, UK.
Saad MarfaniCircadia Technologies Ltd., 6 Delmey Close, London CR0 5QD, UK.ORCID 0000-0002-4074-0287
Guy D LeschzinerCircadia Technologies Ltd., 6 Delmey Close, London CR0 5QD, UK.
Adrian J WilliamsCircadia Technologies Ltd., 6 Delmey Close, London CR0 5QD, UK.
Circassia Pharmaceuticals (United Kingdom) · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Respiratory rate (RR) is typically the first vital sign to change when a patient decompensates. Despite this, RR is often monitored infrequently and inaccurately. The Circadia Contactless Breathing Monitor™ (model C100) is a novel device that uses ultra-wideband radar to monitor RR continuously and un-obtrusively. Performance of the Circadia Monitor was assessed by direct comparison to manually scored reference data. Data were collected across a range of clinical and non-clinical settings, considering a broad range of user characteristics and use cases, in a total of 50 subjects. Bland-Altman analysis showed high agreement with the gold standard reference for all study data, and agreement fell within the predefined acceptance criteria of ±5 breaths per minute (BrPM). The 95% limits of agreement were -3.0 to 1.3 BrPM for a nonprobability sample of subjects while awake, -2.3 to 1.7 BrPM for a clinical sample of subjects while asleep, and -1.2 to 0.7 BrPM for a sample of healthy subjects while asleep. Accuracy rate, using an error margin of ±2 BrPM, was found to be 90% or higher. Results demonstrate that the Circadia Monitor can effectively and efficiently be used for accurate spot measurements and continuous bedside monitoring of RR in low acuity settings, such as the nursing home or hospital ward, or for remote patient monitoring.

Indexed as

RadarRespiratory RateHumansMonitoring, PhysiologicRespirationTechnologyanalysis of agreementcontactless monitorcontinuous vital sign monitoringperformance validationremote patient monitoringrespiratory rate monitorultra-wideband radar

Identifiers

PMID34207961
PMCPMC8230718
OpenAlexW3167816568

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked