Evidence map›Paper›PMID 34207912›Full record

ArticleMicromachines2021

High-Throughput Cell Concentration Using A Piezoelectric Pump in Closed-Loop Viscoelastic Microfluidics.

Jeeyong Kim, Hyunjung Lim, Hyunseul Jee, Seunghee Choo, Minji Yang, Sungha Park, Kyounghwa Lee, Hyoungsook Park, Chaeseung Lim, Jeonghun Nam

Abstract read
In one paragraph

Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jeeyong KimDepartment of Laboratory Medicine, College of Medicine, Korea University, Seoul 08307, Korea.ORCID 0000-0002-0426-2572
Hyunjung LimDepartment of Obstetrics and Gynecology, College of Medicine, Korea University, Seoul 08307, Korea.ORCID 0000-0001-8442-8159
Hyunseul JeeArtificial Intelligence(AI)-Bio Research Center, Incheon Jaeneung University, Incheon 21987, Korea.
Seunghee ChooArtificial Intelligence(AI)-Bio Research Center, Incheon Jaeneung University, Incheon 21987, Korea.
Minji YangArtificial Intelligence(AI)-Bio Research Center, Incheon Jaeneung University, Incheon 21987, Korea.
Sungha ParkArtificial Intelligence(AI)-Bio Research Center, Incheon Jaeneung University, Incheon 21987, Korea.ORCID 0000-0003-1467-3778
Kyounghwa LeeArtificial Intelligence(AI)-Bio Research Center, Incheon Jaeneung University, Incheon 21987, Korea.
Hyoungsook ParkArtificial Intelligence(AI)-Bio Research Center, Incheon Jaeneung University, Incheon 21987, Korea.ORCID 0000-0002-7815-2827
Chaeseung LimDepartment of Laboratory Medicine, College of Medicine, Korea University, Seoul 08307, Korea.
Jeonghun NamArtificial Intelligence(AI)-Bio Research Center, Incheon Jaeneung University, Incheon 21987, Korea.ORCID 0000-0002-0591-7745

Funding

Korea Health Industry Development Institute HR20C0021National Research Foundation of Korea 2020R1A2C1014460
6 · The paper itself

Abstract

Cell concentration is a critical process in biological assays and clinical diagnostics for the pre-treatment of extremely rare disease-related cells. The conventional technique for sample preconcentration and centrifugation has the limitations of a batch process requiring expensive and large equipment. Therefore, a high-throughput continuous cell concentration technique needs to be developed. However, in single-pass operation, the required concentration ratio is hard to achieve. In this study, we propose a closed-loop continuous cell concentration system using a viscoelastic non-Newtonian fluid. For miniaturized and integrated systems, two piezoelectric pumps were adopted. The pumping capability generated by a piezoelectric pump in a microfluidic channel was evaluated depending on the applied voltage, frequency, sample viscosity, and channel length. The concentration performance of the device was evaluated using 13 μm particles and white blood cells (WBCs) with different channel lengths and voltages. In the closed-loop system, the focused cells collected at the center outlet were sent back to the inlet, while the buffer solution was removed to the side outlets. Finally, to expand the clinical applicability of our closed-loop system, WBCs in lysed blood samples with 70% hematocrit and prostate cancer cells in urine samples were used. Using the closed-loop system, WBCs were concentrated by ~63.4 ± 0.8-fold within 20 min to a final volume of 160 μL using 10 mL of lysed blood sample with 70% hematocrit (~3 cP). In addition, prostate cancer cells in 10 mL urine samples were concentrated by ~64.1-fold within ~11 min due to low viscosity (~1 cP).

Indexed as

closed-loopconcentrationhigh-throughputpiezoelectric pumpviscoelastic fluid

Identifiers

PMID34207912
PMCPMC8229193

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.