Collaborative and Structured Network for Maintenance of Mechanical Ventilators during the SARS-CoV-2 Pandemic.

Daniel Motta, Luiz Fernando Taboada Gomes Amaral, Bruno Caetano Dos Santos Silva, Lucas de Freitas Gomes, Willams Teles Barbosa, Rodrigo Santiago Coelho, Bruna Aparecida Souza Machado

Abstract read
In one paragraph

Article in Healthcare (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Daniel MottaPostgraduate Program MPDS/GETEC/MCTI, University Center SENAI CIMATEC, SENAI CIMATEC, Av. Orlando Gomes, 1845 Piatã, Salvador 41650-010, BA, Brazil.
Luiz Fernando Taboada Gomes AmaralPostgraduate Program MPDS/GETEC/MCTI, University Center SENAI CIMATEC, SENAI CIMATEC, Av. Orlando Gomes, 1845 Piatã, Salvador 41650-010, BA, Brazil.
Bruno Caetano Dos Santos SilvaPostgraduate Program MPDS/GETEC/MCTI, University Center SENAI CIMATEC, SENAI CIMATEC, Av. Orlando Gomes, 1845 Piatã, Salvador 41650-010, BA, Brazil.
Lucas de Freitas GomesPostgraduate Program MPDS/GETEC/MCTI, University Center SENAI CIMATEC, SENAI CIMATEC, Av. Orlando Gomes, 1845 Piatã, Salvador 41650-010, BA, Brazil.
Willams Teles BarbosaPostgraduate Program MPDS/GETEC/MCTI, University Center SENAI CIMATEC, SENAI CIMATEC, Av. Orlando Gomes, 1845 Piatã, Salvador 41650-010, BA, Brazil.
Rodrigo Santiago CoelhoPostgraduate Program MPDS/GETEC/MCTI, University Center SENAI CIMATEC, SENAI CIMATEC, Av. Orlando Gomes, 1845 Piatã, Salvador 41650-010, BA, Brazil.
Bruna Aparecida Souza MachadoPostgraduate Program MPDS/GETEC/MCTI, University Center SENAI CIMATEC, SENAI CIMATEC, Av. Orlando Gomes, 1845 Piatã, Salvador 41650-010, BA, Brazil.

Funding

SENAI National Department SENAI National Department
6 · The paper itself

Abstract

The SARS-CoV-2 pandemic in Brazil has grown rapidly since the first case was reported on 26 February 2020. As the pandemic has spread, the low availability of medical equipment has increased, especially mechanical ventilators. The Brazilian Unified Health System (SUS) claimed to have only 40,508 mechanical ventilators, which would be insufficient to support the Brazilian population at the pandemic peak. This lack of ventilators, especially in public hospitals, required quick, assertive, and effective actions to minimize the health crisis. This work provides an overview of the rapid deployment of a network for maintaining disused mechanical ventilators in public and private healthcare units in some regions of Brazil during the SARS-CoV-2 pandemic. Data referring to the processes of maintaining equipment, acquiring parts, and conducting national and international training were collected and analyzed. In total, 4047 ventilators were received by the maintenance sites, and 2516 ventilators were successfully repaired and returned to the healthcare units, which represents a success rate of 62.17%. The results show that the maintenance initiative directly impacted the availability and reliability of the equipment, allowing access to ventilators in the public and private health system and increasing the capacity of beds during the pandemic.

Indexed as

collaborative networkmaintenancemechanical pulmonary ventilatorspandemicSARS-CoV-2