Evidence map›Paper›PMID 34207201›Full record

ArticleInternational journal of environmental research and public health2021

Measurement of Air Pollution Parameters in Montenegro Using the Ecomar System.

Nikola Zaric, Velibor Spalevic, Nikola Bulatovic, Nikola Pavlicevic, Branislav Dudic

Abstract read
In one paragraph

Article in International journal of environmental research and public health, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. High Levels of PM10 Reduce the Physical Activity of Professional Soccer Players.International journal of environmental research and public health · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Nikola ZaricFaculty of Electrical Engineering, University of Montenegro, Cetinjski Put bb, 81000 Podgorica, Montenegro.
Velibor SpalevicDepartment of Soils, Biotechnical Faculty, University of Montenegro, Mihala Lalaica 1, 81000 Podgorica, Montenegro.ORCID 0000-0002-7800-2909
Nikola BulatovicFaculty of Electrical Engineering, University of Montenegro, Cetinjski Put bb, 81000 Podgorica, Montenegro.ORCID 0000-0002-5022-856X
Nikola PavlicevicZTE Corporation, Technical Support Office in Montenegro, 81000 Podgorica, Montenegro.
Branislav DudicFaculty of Management, Comenius University in Bratislava, 82005 Bratislava, Slovakia.ORCID 0000-0002-4647-6026

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Particulate matter air pollution is one of the most dangerous pollutants nowadays and an indirect cause of numerous diseases. A number of these consequences could possibly be avoided if the right information about air pollution were available at a large number of locations, especially in urban areas. Unfortunately, this is not the case today. In the whole of Europe, there are just approximately 3000 automated measuring stations for PM10, and only about 1400 stations equipped for PM2.5 measurement. In order to improve this issue and provide availability of real-time data about air pollution, different low-cost sensor-based solutions are being considered both on-field and in laboratory research. In this paper, we will present the results of PM particle monitoring using a self-developed Ecomar system. Measurements are performed in two cities in Montenegro, at seven different locations during several periods. In total, three Ecomar systems were used during 1107 days of on-field measurements. Measurements performed at two locations near official automated measuring stations during 610 days justified that the Ecomar system performance is satisfying in terms of reliability and measurement precision (NRMSE 0.33 for PM10 and 0.44 for PM2.5) and very high in terms of data validity and operating stability (Ecomar 94.13%-AMS 95.63%). Additionally, five distant urban/rural locations with different traffic, green areas, and nearby industrial objects were utilized to highlight the need for more dense spatial distributions of measuring locations. To our knowledge, this is the most extensive study of low-cost sensor-based air quality measurement systems in terms of the duration of the on-field tests in the Balkan region.

Indexed as

Air PollutantsAir PollutionCitiesEnvironmental MonitoringEuropeMontenegroParticulate MatterReproducibility of ResultsAir PollutantsParticulate Matterair measurementsair pollutionair qualityInternet of ThingsPM particlessensors

Identifiers

PMID34207201
PMCPMC8296430

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.