Evidence map›Paper›PMID 34206718›Full record

ArticleSensors (Basel, Switzerland)2021

An Instance Segmentation and Clustering Model for Energy Audit Assessments in Built Environments: A Multi-Stage Approach.

Youness Arjoune, Sai Peri, Niroop Sugunaraj, Avhishek Biswas, Debanjan Sadhukhan, Prakash Ranganathan

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Youness ArjouneSchool of Electrical Engineering and Computer Science (SEECS), University of North Dakota (UND), Grand Forks, ND 58201, USA.ORCID 0000-0002-8207-0170
Sai PeriSchool of Electrical Engineering and Computer Science (SEECS), University of North Dakota (UND), Grand Forks, ND 58201, USA.
Niroop SugunarajSchool of Electrical Engineering and Computer Science (SEECS), University of North Dakota (UND), Grand Forks, ND 58201, USA.ORCID 0000-0002-6165-0862
Avhishek BiswasSchool of Electrical Engineering and Computer Science (SEECS), University of North Dakota (UND), Grand Forks, ND 58201, USA.
Debanjan SadhukhanSchool of Electrical Engineering and Computer Science (SEECS), University of North Dakota (UND), Grand Forks, ND 58201, USA.
Prakash RanganathanSchool of Electrical Engineering and Computer Science (SEECS), University of North Dakota (UND), Grand Forks, ND 58201, USA.

Funding

North Dakota Department of Commerce (Research ND Program) 22166
6 · The paper itself

Abstract

Heat loss quantification (HLQ) is an essential step in improving a building's thermal performance and optimizing its energy usage. While this problem is well-studied in the literature, most of the existing studies are either qualitative or minimally driven quantitative studies that rely on localized building envelope points and are, thus, not suitable for automated solutions in energy audit applications. This research work is an attempt to fill this gap of knowledge by utilizing intensive thermal data (on the order of 100,000 plus images) and constitutes a relatively new area of analysis in energy audit applications. Specifically, we demonstrate a novel process using deep-learning methods to segment more than 100,000 thermal images collected from an unmanned aerial system (UAS). To quantify the heat loss for a building envelope, multiple stages of computations need to be performed: object detection (using Mask-RCNN/Faster R-CNN), estimating the surface temperature (using two clustering methods), and finally calculating the overall heat transfer coefficient (e.g., the U-value). The proposed model was applied to eleven academic campuses across the state of North Dakota. The preliminary findings indicate that Mask R-CNN outperformed other instance segmentation models with an mIOU of 73% for facades, 55% for windows, 67% for roofs, 24% for doors, and 11% for HVACs. Two clustering methods, namely K-means and threshold-based clustering (TBC), were deployed to estimate surface temperatures with TBC providing consistent estimates across all times of the day over K-means. Our analysis demonstrated that thermal efficiency not only depended on the accurate acquisition of thermal images but also relied on other factors, such as the building geometry and seasonal weather parameters, such as the outside/inside building temperatures, wind, time of day, and indoor heating/cooling conditions. Finally, the resultant U-values of various building envelopes were compared with recommendations from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) building standards.

Indexed as

Air ConditioningBuilt EnvironmentCluster AnalysisHeatingNorth DakotaASHRAEclusteringdeep learningheat loss quantificationinstance segmentationMask R-CNNmean average precisionthermal imageryUASsU-value

Identifiers

PMID34206718
PMCPMC8271532

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390