Evidence map›Paper›PMID 34203107›Full record

ArticleSensors (Basel, Switzerland)2021

The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation.

Andrea Ferretti, Ferdinando Iannotti, Lorenzo Proietti, Carlo Massafra, Attilio Speranza, Andrea Laghi, Raffaele Iorio

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Andrea FerrettiOrthopaedic and Traumatology Unit, Sant'Andrea Hospital, "Sapienza" University of Rome, 00189 Rome, Italy.
Ferdinando IannottiOrthopaedic and Traumatology Unit, Sant'Andrea Hospital, "Sapienza" University of Rome, 00189 Rome, Italy.ORCID 0000-0003-0988-5258
Lorenzo ProiettiOrthopaedic and Traumatology Unit, Sant'Andrea Hospital, "Sapienza" University of Rome, 00189 Rome, Italy.
Carlo MassafraOrthopaedic and Traumatology Unit, Sant'Andrea Hospital, "Sapienza" University of Rome, 00189 Rome, Italy.ORCID 0000-0002-1535-1124
Attilio SperanzaOrthopaedic and Traumatology Unit, Sant'Andrea Hospital, "Sapienza" University of Rome, 00189 Rome, Italy.
Andrea LaghiDepartment of Radiology, Sant'Andrea Hospital, "Sapienza" University of Rome, 00189 Rome, Italy.ORCID 0000-0002-3091-7819
Raffaele IorioOrthopaedic and Traumatology Unit, Sant'Andrea Hospital, "Sapienza" University of Rome, 00189 Rome, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The functional positioning of components in a total hip arthroplasty (THA) and its relationship with individual lumbopelvic kinematics and a patient's anatomy are being extensively studied. Patient-specific kinematic planning could be a game-changer; however, it should be accurately delivered intraoperatively. The main purpose of this study was to verify the reliability and accuracy of a patient-specific instrumentation (PSI) and laser-guided technique to replicate preoperative dynamic planning. Thirty-six patients were prospectively enrolled and received dynamic hip preoperative planning based on three functional lateral spinopelvic X-rays and a low dose CT scan. Three-dimensional (3D) printed PSI guides and laser-guided instrumentation were used intraoperatively. The orientation of the components, osteotomy level and change in hip length and offset were measured on postoperative CT scans and compared with the planned preoperative values. The length of surgery was compared with that of a matched group of thirty-six patients who underwent a conventional THA. The mean absolute deviation from the planned inclination and anteversion was 3.9° and 4.4°, respectively. In 92% of cases, both the inclination and anteversion were within +/- 10° of the planned values. Regarding the osteotomy level, offset change and limb length change, the mean deviation was, respectively, 1.6 mm, 2.6 mm and 2 mm. No statistically significant difference was detected when comparing the planned values with the achieved values. The mean surgical time was 71.4 min in the PSI group and 60.4 min in the conventional THA group (

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisAcetabulumHumansLasersReproducibility of Resultsfunctional orientation of componentspatient-specific dynamic planningpelvic tiltPSIspinopelvic kinematicTHA

Identifiers

PMID34203107
PMCPMC8234047

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.