Evidence map›Paper›PMID 34201834›Full record

ArticleSensors (Basel, Switzerland)2021

Dedicated Algorithm for Unobtrusive Fetal Heart Rate Monitoring Using Multiple Dry Electrodes.

Alessandra Galli, Elisabetta Peri, Yijing Zhang, Rik Vullings, Myrthe van der Ven, Giada Giorgi, Sotir Ouzounov, Pieter J A Harpe, Massimo Mischi

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Alessandra GalliDepartment of Information Engineering, University of Padova, I-35131 Padova, Italy.ORCID 0000-0003-2416-0220
Elisabetta PeriDepartment of Electrical Engineering, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.ORCID 0000-0002-1231-9372
Yijing ZhangDepartment of Electrical Engineering, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.ORCID 0000-0002-6931-0424
Rik VullingsDepartment of Electrical Engineering, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.ORCID 0000-0002-2392-6098
Myrthe van der VenDepartment of Electrical Engineering, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.ORCID 0000-0002-2414-5824
Giada GiorgiDepartment of Information Engineering, University of Padova, I-35131 Padova, Italy.ORCID 0000-0001-9498-4722
Sotir OuzounovPhilips Research, 5656 AE Eindhoven, The Netherlands.ORCID 0000-0003-1961-2317
Pieter J A HarpeDepartment of Electrical Engineering, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.ORCID 0000-0002-6542-0001
Massimo MischiDepartment of Electrical Engineering, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.ORCID 0000-0002-1179-5385

Funding

Nederlandse Organisatie voor Wetenschappelijk Onderzoek NWO HTSM 14663
6 · The paper itself

Abstract

Multi-channel measurements from the maternal abdomen acquired by means of dry electrodes can be employed to promote long-term monitoring of fetal heart rate (fHR). The signals acquired with this type of electrode have a lower signal-to-noise ratio and different artifacts compared to signals acquired with conventional wet electrodes. Therefore, starting from the benchmark algorithm with the best performance for fHR estimation proposed by Varanini et al., we propose a new method specifically designed to remove artifacts typical of dry-electrode recordings. To test the algorithm, experimental textile electrodes were employed that produce artifacts typical of dry and capacitive electrodes. The proposed solution is based on a hybrid (hardware and software) pre-processing step designed specifically to remove the disturbing component typical of signals acquired with these electrodes (triboelectricity artifacts and amplitude modulations). The following main processing steps consist of the removal of the maternal ECG by blind source separation, the enhancement of the fetal ECG and identification of the fetal QRS complexes. Main processing is designed to be robust to the high-amplitude motion artifacts that corrupt the acquisition. The obtained denoising system was compared with the benchmark algorithm both on semi-simulated and on real data. The performance, quantified by means of sensitivity, F1-score and root-mean-square error metrics, outperforms the performance obtained with the original method available in the literature. This result proves that the design of a dedicated processing system based on the signal characteristics is necessary for reliable and accurate estimation of the fHR using dry, textile electrodes.

Indexed as

Heart Rate, FetalSignal Processing, Computer-AssistedAlgorithmsArtifactsElectrocardiographyElectrodesFemaleHumansPregnancyartifacts removalblind source separationdry electrodesfetal heart rate monitoringmulti-channel measurementstextile electrodes

Identifiers

PMID34201834
PMCPMC8271482

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.