Evidence map›Paper›PMID 34201480›Full record

ArticleBiosensors2021

Epileptic Seizure Detection on an Ultra-Low-Power Embedded RISC-V Processor Using a Convolutional Neural Network.

Andreas Bahr, Matthias Schneider, Maria Avitha Francis, Hendrik M Lehmann, Igor Barg, Anna-Sophia Buschhoff, Peer Wulff, Thomas Strunskus, Franz Faupel

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 31 citations in OpenAlex.

  1. Full-Stack Architectures for Intelligent Brain-Computer Interfaces.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Andreas BahrSensor System Electronics, Institute of Electrical Engineering and Information Technology, Kiel University, 24143 Kiel, Germany.ORCID 0000-0001-8012-6794
Matthias SchneiderSensor System Electronics, Institute of Electrical Engineering and Information Technology, Kiel University, 24143 Kiel, Germany.
Maria Avitha FrancisSensor System Electronics, Institute of Electrical Engineering and Information Technology, Kiel University, 24143 Kiel, Germany.
Hendrik M LehmannCMOS Design, Technical University Braunschweig, 38106 Braunschweig, Germany.
Igor BargMulticomponent Materials, Institute for Material Science, Kiel University, 24143 Kiel, Germany.
Anna-Sophia BuschhoffInstitute of Physiology, Kiel University, 24118 Kiel, Germany.
Peer WulffInstitute of Physiology, Kiel University, 24118 Kiel, Germany.
Thomas StrunskusMulticomponent Materials, Institute for Material Science, Kiel University, 24143 Kiel, Germany.ORCID 0000-0003-3931-5635
Franz FaupelMulticomponent Materials, Institute for Material Science, Kiel University, 24143 Kiel, Germany.ORCID 0000-0003-3367-1655
Hochschule für Angewandte Wissenschaften Kiel · DEChristian-Albrechts-Universität zu Kiel · DETechnische Universität Braunschweig · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The treatment of refractory epilepsy via closed-loop implantable devices that act on seizures either by drug release or electrostimulation is a highly attractive option. For such implantable medical devices, efficient and low energy consumption, small size, and efficient processing architectures are essential. To meet these requirements, epileptic seizure detection by analysis and classification of brain signals with a convolutional neural network (CNN) is an attractive approach. This work presents a CNN for epileptic seizure detection capable of running on an ultra-low-power microprocessor. The CNN is implemented and optimized in MATLAB. In addition, the CNN is also implemented on a GAP8 microprocessor with RISC-V architecture. The training, optimization, and evaluation of the proposed CNN are based on the CHB-MIT dataset. The CNN reaches a median sensitivity of 90% and a very high specificity over 99% corresponding to a median false positive rate of 6.8 s per hour. After implementation of the CNN on the microcontroller, a sensitivity of 85% is reached. The classification of 1 s of EEG data takes t=35 ms and consumes an average power of P≈140 μW. The proposed detector outperforms related approaches in terms of power consumption by a factor of 6. The universal applicability of the proposed CNN based detector is verified with recording of epileptic rats. This results enable the design of future medical devices for epilepsy treatment.

Indexed as

Neural Networks, ComputerAlgorithmsAnimalsBrainElectroencephalographyEpilepsyHumansRatsSeizuresconvolutional neural networkEEGepileptic seizure detectionRISC-Vultra-low-power

Identifiers

PMID34201480
PMCPMC8301882
OpenAlexW3174796407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked