Evidence map›Paper›PMID 34201129›Full record

ArticleMicromachines2021

Numerical Evaluation on Residual Thermal Stress-Induced Delamination at PDMS-Metal Interface of Neural Prostheses.

Yuyang Mao, Ivan Pechenizkiy, Thomas Stieglitz, Theodor Doll

Abstract read
In one paragraph

Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yuyang MaoBioMaterial Engineering, Department of Otorhinolaryngology, Hannover Medical School, Carl Neuberg-Str. 1, 30625 Hannover, Germany.ORCID 0000-0002-2059-3777
Ivan PechenizkiyBioMaterial Engineering, Department of Otorhinolaryngology, Hannover Medical School, Carl Neuberg-Str. 1, 30625 Hannover, Germany.
Thomas StieglitzLaboratory for Biomedical Microtechnology, Department of Microsystems Engineering-IMTEK & BrainLinks-BrainTools Center, University of Freiburg, 79110 Freiburg, Germany.ORCID 0000-0002-7349-4254
Theodor DollBioMaterial Engineering, Department of Otorhinolaryngology, Hannover Medical School, Carl Neuberg-Str. 1, 30625 Hannover, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The most common failure mode of implantable neural implants has been delamination of layers in compound structures and encapsulations in a wet body environment. Current knowledge of failure mechanisms of adhesion and its standardized test procedures are lacking and must be established. This study demonstrated a combined experimental and numerical method to investigate the residual stresses from one of the most common encapsulation materials, silicone rubber (polydimethylsiloxane-PDMS) during the coating process at elevated temperatures. Measured shrinkage of test specimen correlates well to a modified shrinkage model using thermal-mechanical finite element method (FEM) simulation. All simulated interfacial stresses show stress concentration at the PDMS coating front depending on curing temperature and coating thickness, while Griffith's condition estimated the delamination of the coating front. This study emphasizes the understanding of the interfacial delamination giving the possibility to predict failure mode of neural interface.

Indexed as

adhesiondelaminationneural electrodesneural implantpolydimethylsiloxane-PDMSresidual stressesshrinkage

Identifiers

PMID34201129
PMCPMC8226984

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials