Evidence map›Paper›PMID 34200031›Full record

ArticleJournal of personalized medicine2021

Restoring the Patient's Pre-Arthritic Posterior Slope Is the Correct Target for Maximizing Internal Tibial Rotation When Implanting a PCL Retaining TKA with Calipered Kinematic Alignment.

Alexander J Nedopil, Connor Delman, Stephen M Howell, Maury L Hull

Abstract read
In one paragraph

Article in Journal of personalized medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Alexander J NedopilOrthopädische Klinik König-Ludwig-Haus, Lehrstuhl für Orthopädie der Universität Würzburg, 97074 Würzburg, Germany.ORCID 0000-0002-3655-158X
Connor DelmanDepartment of Orthopedic Surgery, University of California, Davis, CA 95817, USA.
Stephen M HowellDepartment of Biomedical Engineering, University of California, Davis, CA 95616, USA.ORCID 0000-0001-8184-0324
Maury L HullDepartment of Biomedical Engineering, University of California, Davis, CA 95616, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe calipered kinematically-aligned (KA) total knee arthroplasty (TKA) strives to restore the patient's individual pre-arthritic (i.e., native) posterior tibial slope when retaining the posterior cruciate ligament (PCL). Deviations from the patient's individual pre-arthritic posterior slope tighten and slacken the PCL in flexion that drives tibial rotation, and such a change might compromise passive internal tibial rotation and coupled patellofemoral kinematics.

methodsTwenty-one patients were treated with a calipered KA TKA and a PCL retaining implant with a medial ball-in-socket and a lateral flat articular insert conformity that mimics the native (i.e., healthy) knee. The slope of the tibial resection was set parallel to the medial joint line by adjusting the plane of an angel wing inserted in the tibial guide. Three trial inserts that matched and deviated 2°> and 2°< from the patient's pre-arthritic slope were 3D printed with goniometric markings. The goniometer measured the orientation of the tibia (i.e., trial insert) relative to the femoral component.

resultsThere was no difference between the radiographic preoperative and postoperative tibial slope (0.7 ± 3.2°, NS). From extension to 90° flexion, the mean passive internal tibial rotation with the pre-arthritic slope insert of 19° was greater than the 15° for the 2°> slope ( DISCUSSION: When performing a calipered KA TKA with PCL retention, the correct target for setting the tibial component is the patient's individual pre-arthritic slope within a tolerance of ±2°, as this target resulted in a 15-19° range of internal tibial rotation that is comparable to the 15-18° range reported for the native knee from extension to 90° flexion.

Indexed as

kinematic alignmentrotationslopetotal knee arthroplastytotal knee replacement

Identifiers

PMID34200031
PMCPMC8228254

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.