ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2021
High fidelity triangular sweep of the magnetic field for millisecond scan EPR imaging.
Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Amiodarone Advances the Apoptosis of Cardiomyocytes by Repressing Sigmar1 Expression and Blocking KCNH2-related Potassium Channels.Current molecular medicine · 2025Article
- Partial Acquisition of Spectral Projections Accelerates Four-dimensional Spectral-spatial EPR Imaging for Mouse Tumor Models: A Feasibility Study.Molecular imaging and biology · 2024Article
- δ-Opioid Receptor as a Molecular Target for Increasing Cardiac Resistance to Reperfusion in Drug Development.Biomedicines · 2023Review
- Electron Paramagnetic Resonance Implemented with Multiple Harmonic Detections Successfully Maps Extracellular pH In Vivo.Analytical chemistry · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Linearity of the magnetic field sweep is important for high resolution continuous wave EPR imaging. Driving the field with triangular wave function is the most efficient way to scan EPR projections. However, the magnetic field sweep profile can be significantly distorted during fast millisecond projection scan. In this work, we introduce a method to generate highly linear and properly symmetrical triangular sweeps of the magnetic field using calibrated harmonics of the triangular wave function. First, the frequency response function of the EPR magnet and its power circuitry was obtained. For this, the field sweeping coil was driven with sinusoidal signals of different frequencies and the actual magnetic field inside the magnet was recorded. To cover wide range of frequencies, the measurements were carried out independently using gaussmeter, Hall-effect linear sensor integrated circuit, and an inductance coil. For each frequency, the system gain and the phase delay were determined. These data were used to adjust the amplitudes and the phases of individual harmonics of the triangular wave function. After the calibration, the maximum deviation of the magnetic field from the linear function was 0.05% of sweep width for 4 ms scan. The maximum discrepancy between the forward and the reverse scan was less than 0.04%. Sweep overhead time for changing the scan direction was 5%. The proposed approach allows generation of high fidelity triangular magnetic field sweeps with accuracy better than 0.1% for the range of the magnetic field sweep widths up to 48 G and scan duration from 10 s down to 1 ms.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.