Trial reportJournal of cardiovascular electrophysiology2021
Ultralow temperature cryoablation using near-critical nitrogen for cavotricuspid isthmus-ablation, first-in-human results.
Trial report in Journal of cardiovascular electrophysiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Prospective, Multicenter, Investigation of the Adagio PolarStar System in Subjects With Atrial Flutter
A Prospective, Multicenter Investigation of the Adagio Cryoablation System in Patients With Atrial Fibrillation
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.
- Esophageal injury, perforation, and fistula formation following atrial fibrillation ablation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2024Pooled it
- Ultralow temperature cryoablation using near-critical nitrogen for cavotricuspid isthmus-ablation, first-in-human results.Journal of cardiovascular electrophysiology · 2021Trial
- Efficacy and safety of pulsed field ablation for cavotricuspid isthmus-dependent atrial flutter: A meta-analysis based on real-world evidence.Heart rhythm O2 · 2026Article
- Catheter Ablation of Ventricular Tachycardia in Ischemic Heart Disease: What Is Known and New Perspectives.Current heart failure reports · 2024Review
- Isolation of the superior vena cava by ultra-low temperature cryoablation.Journal of arrhythmia · 2024Article
- Synthesis of Manganese Zinc Ferrite Nanoparticles in Medical-Grade Silicone for MRI Applications.International journal of molecular sciences · 2023Article
- Novel case of linear ultra-low cryoablation catheter for treatment of ventricular tachycardia.HeartRhythm case reports · 2022Article
- Preventing esophageal complications from atrial fibrillation ablation: A review.Heart rhythm O2 · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionCryoablation has evolved as a safe alternative to radiofrequency ablation in the treatment of several supraventricular arrhythmias and has potential advantages, yet is limited by the properties of the cryogen used. We investigated a novel ultralow temperature cryoablation (ULTC) system using nitrogen near its liquid-vapor critical point as a freezing source, achieving temperatures as low as -196 degrees Celsius in a long linear catheter with a continuous energy release. Initial safety, procedural and efficacy outcomes of ULTC are described in patients undergoing cavotricuspid isthmus (CTI) ablation. METHODS AND
resultsThe Cryocure studies (NCT02355106, NCT02839304) are prospective, single-arm, multi-center, first-in-human clinical studies in 17 patients with atrial flutter (AFL) and 13 patients with atrial fibrillation (AF). A total of 30 patients, mean age 65 ± 8 years old and 67% male, were enrolled and underwent ablation of the CTI. Acute success, defined as the confirmation of stable bidirectional conduction block across the CTI, was achieved in all 30 patients. After 12 months of follow-up, 14 out of 17 AFL patients remained free from any AFL. One (3.3%) procedure-related but not device-related serious adverse event was reported, involving transient inferolateral ST-elevation associated with temporary AV conduction block.
conclusionIn this first-in-human clinical study the safety and performance results demonstrate the capabilities of ultralow temperature near-critical nitrogen as an effective energy source for CTI ablation. Ongoing, larger, studies should confirm our findings and evaluate the capabilities to create linear and focal transmural lesions in other arrhythmias.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.