Evidence map›Paper›PMID 34196697›Full record

ArticleJournal of radiation research2021

Prediction of target position from multiple fiducial markers by partial least squares regression in real-time tumor-tracking radiation therapy.

Kanako Ukon, Yohei Arai, Seishin Takao, Taeko Matsuura, Masayori Ishikawa, Hiroki Shirato, Shinichi Shimizu, Kikuo Umegaki, Naoki Miyamoto

Open access · goldAbstract read
In one paragraph

Article in Journal of radiation research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Kanako UkonGraduate School of Medicine, Hokkaido University, North 15, West 7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan.
Yohei AraiGraduate School of Engineering, Hokkaido University, North 13, West 8, Kita-ku, Sapporo, Hokkaido 060-8628, Japan.
Seishin TakaoDepartment of Medical Physics, Hokkaido University Hospital, North 14, West 5, Kita-ku, Sapporo, Hokkaido 060-8648, Japan.
Taeko MatsuuraDepartment of Medical Physics, Hokkaido University Hospital, North 14, West 5, Kita-ku, Sapporo, Hokkaido 060-8648, Japan.
Masayori IshikawaFaculty of Health Sciences, Hokkaido University, North12, West 5, Kita-ku, Sapporo, Hokkaido 060-0812, Japan.
Hiroki ShiratoFaculty of Medicine, Hokkaido University, North 15, West 7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan.
Shinichi ShimizuDepartment of Medical Physics, Hokkaido University Hospital, North 14, West 5, Kita-ku, Sapporo, Hokkaido 060-8648, Japan.
Kikuo UmegakiFaculty of Engineering, Hokkaido University, North13, West 8, Kita-ku, Sapporo, Hokkaido 060-8628, Japan.
Naoki MiyamotoDepartment of Medical Physics, Hokkaido University Hospital, North 14, West 5, Kita-ku, Sapporo, Hokkaido 060-8648, Japan.
Hokkaido University · JPHokkaido University Hospital · JP

Funding

KAKENHI 18 K19887
6 · The paper itself

Abstract

The purpose of this work is to show the usefulness of a prediction method of tumor location based on partial least squares regression (PLSR) using multiple fiducial markers. The trajectory data of respiratory motion of four internal fiducial markers inserted in lungs were used for the analysis. The position of one of the four markers was assumed to be the tumor position and was predicted by other three fiducial markers. Regression coefficients for prediction of the position of the tumor-assumed marker from the fiducial markers' positions is derived by PLSR. The tracking error and the gating error were evaluated assuming two possible variations. First, the variation of the position definition of the tumor and the markers on treatment planning computed tomograhy (CT) images. Second, the intra-fractional anatomical variation which leads the distance change between the tumor and markers during the course of treatment. For comparison, rigid predictions and ordinally multiple linear regression (MLR) predictions were also evaluated. The tracking and gating errors of PLSR prediction were smaller than those of other prediction methods. Ninety-fifth percentile of tracking/gating error in all trials were 3.7/4.1 mm, respectively in PLSR prediction for superior-inferior direction. The results suggested that PLSR prediction was robust to variations, and clinically applicable accuracy could be achievable for targeting tumors.

Indexed as

Computer SystemsFiducial MarkersFour-Dimensional Computed TomographyImaging, Three-DimensionalLeast-Squares AnalysisRadiography, InterventionalDiagnostic ErrorsFluoroscopyHumansImage Processing, Computer-AssistedLinear ModelsMotionNeoplasmsRadiotherapy Planning, Computer-AssistedRespirationfiducial markergating irradiationpartial least squares regression (PLSR)real-time tumor-tracking radiation therapytracking irradiation

Identifiers

PMID34196697
PMCPMC8438269
OpenAlexW3173751686

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.