Radiographic and fluoroscopic X-ray systems: Quality control of the X-ray tube and automatic exposure control using theoretical spectra to determine air kerma and dose to a homogenous phantom.

Bente Konst, Jacob Nøtthellen, Ellinor Bilet, Magnus Båth

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 2 countries.

Bente KonstDepartment of Radiology, Vestfold Hospital Trust, Tønsberg, Norway.
Jacob NøtthellenDivision of Diagnostics and Intervention, Oslo University Hospital, Oslo, Norway.
Ellinor BiletNorwegian Hospital Construction Agency, Trondheim, Norway.
Magnus BåthDepartment of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden.
Norwegian Environment Agency · NOOslo University Hospital · NOSykehuset i Vestfold · NOUniversity of Gothenburg · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo develop a method to perform quality control (QC) of X-ray tubes and automatic exposure control (AEC) as a part of the QC of the radiographic and fluoroscopic X-ray system. Our aim is to verify the output from the X-ray tube by comparing the measured radiation output, or air kerma, to the theoretical output given the applied exposure settings and geometry, in addition to comparing the measured kV to the nominal kV. The AEC system for fluoroscopic and conventional X-ray systems is assessed by determining the absorbed dose to a homogenous phantom with different thicknesses.

methodThis study presents a model to verify the X-ray tube measurement results and a method to determine the dose to a homogenous phantom (D

resultsThe spectrum provided in this study was in good agreement with two previously published X-ray spectra. The absolute percentage differences of the spectra varied from 0.05% to 3.9%, with an average of 1.4%, compared to SpekCalc. Similarly, the deviation from IPEM report 78 varied from 0.02% to 2.3%, with an average of 0.74%. The SPECTRUM was parameterized for calculation of the imparted fraction for target angles of 10°, 12°, and 15°, kV (50-150 kV) with the materials Al (2.2-8 mm), Cu (0-1 mm), and any combination of the filters, PMMA and water. The deviation of energy imparted from the results by PCXMC was less than 8% for all measurements across different kV, filtration, and vendors, obtained by using PMMA to record the exposure parameters, while the dose was calculated based on water with same thicknesses as the PMMA.

conclusionThis study presents an accurate and suitable method to perform a part of the QC of fluoroscopic and conventional X-ray systems with respect to the X-ray tube and the associated AEC system. The method is suitable for comparing protocols within and between systems via the absorbed dose.

Indexed as

X-RaysFluoroscopyHumansMonte Carlo MethodPhantoms, ImagingQuality ControlRadiation Dosageabsorbed doseair kermaautomatic exposure controlfluoroscopyquality controlradiographyX-ray tube

Identifiers

PMID34196461
PMCPMC8364276
OpenAlexW3174477215

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.