Evidence map›Paper›PMID 34196137›Full record

ArticleJournal of biomedical optics2021

CNN-based CP-OCT sensor integrated with a subretinal injector for retinal boundary tracking and injection guidance.

Soohyun Lee, Jin Kang

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. High-resolutionBiomedical optics express · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Soohyun LeeJohns Hopkins Univ., United States.
Jin KangJohns Hopkins Univ., United States.
Johns Hopkins University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceSubretinal injection is an effective way of delivering transplant genes and cells to treat many degenerative retinal diseases. However, the technique requires high-dexterity and microscale precision of experienced surgeons, who have to overcome the physiological hand tremor and limited visualization of the subretinal space.

aimTo automatically guide the axial motion of microsurgical tools (i.e., a subretinal injector) with microscale precision in real time using a fiber-optic common-path swept-source optical coherence tomography distal sensor. APPROACH: We propose, implement, and study real-time retinal boundary tracking of A-scan optical coherence tomography (OCT) images using a convolutional neural network (CNN) for automatic depth targeting of a selected retinal boundary for accurate subretinal injection guidance. A simplified 1D U-net is used for the retinal layer segmentation on A-scan OCT images. A Kalman filter, combining retinal boundary position measurement by CNN and velocity measurement by cross correlation between consecutive A-scan images, is applied to optimally estimate the retinal boundary position. Unwanted axial motions of the surgical tools are compensated by a piezoelectric linear motor based on the retinal boundary tracking.

resultsCNN-based segmentation on A-scan OCT images achieves the mean unsigned error (MUE) of ∼3  pixels (8.1  μm) using an ex vivo bovine retina model. GPU parallel computing allows real-time inference (∼2  ms) and thus real-time retinal boundary tracking. Involuntary tremors, which include low-frequency draft in hundreds of micrometers and physiological tremors in tens of micrometers, are compensated effectively. The standard deviations of photoreceptor (PR) and choroid (CH) boundary positions get as low as 10.8  μm when the depth targeting is activated.

conclusionsA CNN-based common-path OCT distal sensor successfully tracks retinal boundaries, especially the PR/CH boundary for subretinal injection, and automatically guides the tooltip's axial position in real time. The microscale depth targeting accuracy of our system shows its promising possibility for clinical application.

Indexed as

Retinal DiseasesTomography, Optical CoherenceAnimalsCattleChoroidNeural Networks, ComputerRetinaconvolutional neural networkmicrosurgeryoptical coherence tomographyretinal segmentationsurgical guidance

Identifiers

PMID34196137
PMCPMC8242537
OpenAlexW3176683823

What OpenQuestion holds