Evidence map›Paper›PMID 34193431›Full record

ArticleScience advances2021

Long-term reliable physical health monitoring by sweat pore-inspired perforated electronic skins.

Hanwool Yeon, Haneol Lee, Yeongin Kim, Doyoon Lee, Youngjoo Lee, Jong-Sung Lee, Jiho Shin, Chanyeol Choi, Ji-Hoon Kang, Jun Min Suh and 16 more

Open access · goldAbstract read
In one paragraph

Article in Science advances, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed
10.8field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

34 citing papers in PubMed, 171 citations in OpenAlex.

  1. Review
  2. Article
  3. Wearable Flexible Sensors for Cardiovascular Disease Monitoring.Advanced materials (Deerfield Beach, Fla.) · 2026
    Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Multimodal flexible sensor system toward telediagnosis.Proceedings of the Japan Academy. Series B, Physical and biological sciences · 2026
    Review
  9. Article
  10. Review
  11. Article
  12. Article
  13. Review
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

26 authors at 7 institutions in 3 countries.

Hanwool YeonDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.ORCID http://orcid.org/0000-0002-0047-6872
Haneol LeeDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.ORCID http://orcid.org/0000-0003-2866-5947
Yeongin KimDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.ORCID http://orcid.org/0000-0002-9495-3165
Doyoon LeeDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.ORCID http://orcid.org/0000-0003-4355-8146
Youngjoo LeeDepartment of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA.
Jong-Sung LeeDepartment of Materials Science and Engineering, Seoul National University, Seoul, South Korea.
Jiho ShinDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Chanyeol ChoiResearch Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.ORCID http://orcid.org/0000-0003-3304-3253
Ji-Hoon KangDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Jun Min SuhDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.ORCID http://orcid.org/0000-0001-8506-0739
Hyunseok KimDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.ORCID http://orcid.org/0000-0003-3091-8413
Hyun S KumDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.ORCID http://orcid.org/0000-0002-8009-569X
Jaeyong LeeDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Daeyeon KimCenter for Opto-Electronic Materials and Devices, Korea Institute of Science and Technology, Seoul, South Korea.ORCID http://orcid.org/0000-0001-5632-2509
Kyul KoCenter for Opto-Electronic Materials and Devices, Korea Institute of Science and Technology, Seoul, South Korea.ORCID http://orcid.org/0000-0002-6394-7379
Boo Soo MaCenter for Opto-Electronic Materials and Devices, Korea Institute of Science and Technology, Seoul, South Korea.
Peng LinDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.ORCID http://orcid.org/0000-0002-0679-8063
Sangwook HanDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Sungkyu KimDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Sang-Hoon BaeDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Taek-Soo KimDepartment of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea.
Min-Chul ParkCenter for Opto-Electronic Materials and Devices, Korea Institute of Science and Technology, Seoul, South Korea.ORCID http://orcid.org/0000-0002-8575-085X
Young-Chang JooDepartment of Materials Science and Engineering, Seoul National University, Seoul, South Korea.ORCID http://orcid.org/0000-0003-2562-375X
Eunjoo KimSkincare Division, Amorepacific R&D Center, Yongin, South Korea.ORCID http://orcid.org/0000-0002-3032-5303
Jiyeon HanDepartment of Dermatology, Chung Ang University College of Medicine, Seoul, South Korea. sviviria@amorepacific.com jeehwan@mit.edu.ORCID http://orcid.org/0000-0002-7606-5009
Jeehwan KimDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. sviviria@amorepacific.com jeehwan@mit.edu.ORCID http://orcid.org/0000-0002-1547-0967
Massachusetts Institute of Technology · USSeoul National University · KRKorea Institute of Science and Technology · KRAmorepacific (South Korea) · KRChung-Ang University · KRKorea Advanced Institute of Science and Technology · KRSejong University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electronic skins (e-skins)-electronic sensors mechanically compliant to human skin-have long been developed as an ideal electronic platform for noninvasive human health monitoring. For reliable physical health monitoring, the interface between the e-skin and human skin must be conformal and intact consistently. However, conventional e-skins cannot perfectly permeate sweat in normal day-to-day activities, resulting in degradation of the intimate interface over time and impeding stable physical sensing. Here, we present a sweat pore-inspired perforated e-skin that can effectively suppress sweat accumulation and allow inorganic sensors to obtain physical health information without malfunctioning. The auxetic dumbbell through-hole patterns in perforated e-skins lead to synergistic effects on physical properties including mechanical reliability, conformability, areal mass density, and adhesion to the skin. The perforated e-skin allows one to laminate onto the skin with consistent homeostasis, enabling multiple inorganic sensors on the skin to reliably monitor the wearer's health over a period of weeks.

Identifiers

PMID34193431
PMCPMC8245037
OpenAlexW3176312517

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.