Evidence map›Paper›PMID 34191498›Full record

ArticleACS sensors2021

Enhanced Microfluidic Sample Homogeneity and Improved Antibody-Based Assay Kinetics Due to Magnetic Mixing.

Eriola-Sophia Shanko, Lennard Ceelen, Ye Wang, Yoeri van de Burgt, Jaap den Toonder

Open access · greenAbstract read
In one paragraph

Article in ACS sensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Magnetic Bead Manipulation in Microfluidic Chips for Biological Application.Cyborg and bionic systems (Washington, D.C.) · 2023
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Eriola-Sophia ShankoMicrosystems Research Section, Department of Mechanical Engineering, and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600MB, The Netherlands.ORCID 0000-0002-7674-3893
Lennard CeelenMicrosystems Research Section, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven 5600MB, The Netherlands.
Ye WangMicrosystems Research Section, Department of Mechanical Engineering, and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600MB, The Netherlands.
Yoeri van de BurgtMicrosystems Research Section, Department of Mechanical Engineering, and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600MB, The Netherlands.ORCID 0000-0003-3472-0148
Jaap den ToonderMicrosystems Research Section, Department of Mechanical Engineering, and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600MB, The Netherlands.
Eindhoven University of Technology · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recent global events have distinctly demonstrated the need for fast diagnostic analysis of targets in a liquid sample. However, microfluidic lab-on-a-chip devices for point-of-care diagnostics can suffer from slow analysis due to poor mixing. Here, we experimentally explore the mixing effect within a microfluidic chamber, as obtained from superparamagnetic beads exposed to an out-of-plane (vertical) rotating magnetic field. Various magnetic protocols are explored, and the level of sample homogeneity is measured by determining the mixing efficiency index. In particular, we introduce a method to induce effective mixing in a microfluidic chamber by the actuation of the same beads to perform global swarming behavior, a collective motion of a large number of individual entities often seen in nature. The microparticle swarming induces high fluid velocities in initially stagnant fluids, and it can be externally controlled. The method is pilot-tested using a point-of-care test featuring a bioluminescent assay for the detection of antibodies. The mixing by the magnetic beads leads to increased assay kinetics, which indeed reduces the time to sensor readout substantially. Magnetic microparticle swarming is expected to be beneficial for a wide variety of point-of-care devices, where fast homogeneity of reagents does play a role.

Indexed as

MagneticsMicrofluidicsKineticsLab-On-A-Chip DevicesMagnetic Fieldsantibody testingmicrofluidicsmicromixingsuperparamagnetic beadsswarming

Identifiers

PMID34191498
PMCPMC8457298
OpenAlexW3176166391

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.