Best practice for the nuclear medicine technologist in CT-based attenuation correction and calcium score for nuclear cardiology.
Review in European journal of hybrid imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Time-efficient cardiac imaging: early post-injection stress-first protocol myocardial perfusion SPECT with a CZT camera.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023Article
- Accurate and efficient rapid acquisition early post-injection stress-first CZT SPECT myocardial perfusion imaging with tetrofosmin and attenuation correction.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023Article
- EANM procedural recommendations for managing the paediatric patient in diagnostic nuclear medicine.European journal of nuclear medicine and molecular imaging · 2023Review
- The influence of arm positions on mechanical dyssynchrony measured by gated myocardial perfusion imaging.Quantitative imaging in medicine and surgery · 2023Article
- Evaluation of the cardiac subvolume dose and myocardial perfusion in left breast cancer patients with postoperative radiotherapy: a prospective study.Scientific reports · 2023Observational
- Myocardial Perfusion Single-Photon Emission Computed Tomography (SPECT) Image Denoising: A Comparative Study.Diagnostics (Basel, Switzerland) · 2023Article
- Clinical Application of Myocardial Perfusion SPECT in Patients with Suspected or Known Coronary Artery Disease. What Role in the Multimodality Imaging Era?Reviews in cardiovascular medicine · 2023Review
- High Coronary Artery Calcium Score Is Associated With Increased Major Adverse Cardiac Events After Liver Transplantation.Transplantation direct · 2023Article
- First-pass cardiac PET: Potentiality and limitations.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022Article
- A two-stage cardiac PET and late gadolinium enhancement MRI co-registration method for improved assessment of non-ischemic cardiomyopathies using integrated PET/MR.European journal of nuclear medicine and molecular imaging · 2022Article
- Clinical Application of Dynamic SPECT/CT in a Patient with Prior Myocardial Infarction Underwent Percutaneous Coronary Intervention Twice.Diagnostics (Basel, Switzerland) · 2021Article
- Myocardial Flow Reserve Measurement During CZT-SPECT Perfusion Imaging for Coronary Artery Disease Screening: Correlation With Clinical Findings and Invasive Coronary Angiography-The CFR-OR Study.Frontiers in medicine · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The use of hybrid systems is increasingly growing in Europe and this is progressively important for the final result of diagnostic tests. As an integral part of the hybrid imaging system, computed tomography (CT) plays a crucial role in myocardial perfusion imaging diagnostics. Throughout Europe, a variety of equipment is available and also different university curricula of the nuclear medicine technologist are observed. Hence, the Technologist Committee of the European Association of Nuclear Medicine proposes to identify, through a bibliographic review, the recommendations for best practice in computed tomography applied to attenuation correction and calcium score in myocardial perfusion imaging, which courses in the set of knowledge, skills, and competencies for nuclear medicine technologists. This document aims at providing recommendations for CT acquisition protocols and CT image optimization in nuclear cardiology.