Evidence map›Paper›PMID 34189117›Full record

ArticleJournal of biomedical physics & engineering2021

Equivalent Dose and Risk of Exposure Induced Cancer Death of Different Organs due to Various Image Techniques of EOS Imaging System.

Nima Hamzian, Saeid Afereydoon, Mahdi Ghorbani, Seyed Mohammad Jalil Abrisham, Zahra Roozmand, Sepideh Abdollahi-Dehkordi, Morteza Sepehr Javan, Mohammad Reza Deevband

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical physics & engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Radioprotective Effect ofJournal of biomedical physics & engineering · 2022
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Nima HamzianPhD, Department of Medical Physics, School of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Saeid AfereydoonMSc, Department of Medical Physics, School of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Mahdi GhorbaniPhD, Department of Biomedical Engineering and Medical Physics, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Seyed Mohammad Jalil AbrishamMD, Department of EOS Imaging, Shahid Sadoughi General Hospital, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Zahra RoozmandBSc, Department of Medical Physics, School of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Sepideh Abdollahi-DehkordiMSc, Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
Morteza Sepehr JavanBSc, Department of EOS Imaging, Shahid Sadoughi General Hospital, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Mohammad Reza DeevbandPhD, Department of Biomedical Engineering and Medical Physics, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Shahid Sadoughi University of Medical Sciences and Health Services · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEuronext Paris Advanced Orthopedic Solutions (EOS) system is a new radiography system, capable of obtaining two-dimensional and three-dimensional images from bony structures in the body.

objectiveThe aim of this study is to estimate equivalent dose and the risk of exposure induced cancer death (REID) in different organs of body due to EOS imaging system. MATERIAL AND

methodsIn this experimental study, totally 120 patients were evaluated for various imaging techniques of lower limb, full spine and whole body. Equivalent dose and REID for colon, liver, lung, stomach, breast, bladder, ovary, blood cells (leukemia) and other organs were calculated using PCXMC software (version 2.0.1.2) based on Monte Carlo simulation of X-ray and human phantoms. The data on imaging technique, including age, sex, kVp, dose area product (DAP), mA, focal to detector distance were introduced as the input of PCXMC.

resultsThe maximum equivalent dose (mSv) due to EOS imaging system, was estimated for the bladder 0.240±0.066 for the full body technique and 0.240±0.093 for the lower limb technique, respectively, in both males and females. The maximum organ REID (incidence per million) due to EOS imaging system was estimated for lungs as 2.59±1.0 and 2.53±0.9, for the full body technique in both males and females, respectively.

conclusionGenerally, the equivalent dose and REID by EOS imaging system in different organs of body is low due to the low radiation dose received by the body in different techniques and views.

Indexed as

EOS Imaging SystemRadiation DosageRadiation EffectsRadiographyRisk of Exposure induced Cancer Death

Identifiers

PMID34189117
PMCPMC8236105
OpenAlexW3172644393

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.