Evidence map›Paper›PMID 34189016›Full record

ArticleSustainable cities and society2021

Experimental study on the control effect of different ventilation systems on fine particles in a simulated hospital ward.

Xiangfei Kong, Chenli Guo, Zhang Lin, Shasha Duan, Junjie He, Yue Ren, Jianlin Ren

Open access · greenAbstract read
In one paragraph

Article in Sustainable cities and society, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
13.5field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 117 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Xiangfei KongSchool of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China.
Chenli GuoSchool of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China.
Zhang LinCity University of Hong Kong Shenzhen Research Institute, Shenzhen, China.
Shasha DuanSchool of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China.
Junjie HeSchool of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China.
Yue RenSchool of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China.
Jianlin RenSchool of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, China.
Hebei University of Technology · CNCity University of Hong Kong · HK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In recent years, a large number of respiratory infectious diseases (especially COVID-19) have broken out worldwide. Respiratory infectious viruses may be released in the air, resulting in cross-infection between patients and medical workers. Indoor ventilation systems can be adjusted to affect fine particles containing viruses. This study was aimed at performing a series of experiments to evaluate the ventilation performance and assess the exposure of healthcare workers (HW) to virus-laden particles released by patients in a confined experimental chamber. In a typical ward setting, four categories (top supply and exhaust, side supply and exhaust) were evaluated, encompassing 16 different air distribution patterns. The maximum reduction in the cumulative exposure level for HW was 70.8% in ventilation strategy D (upper diffusers on the sidewall supply and lower diffusers on the same sidewall return). The minimum value of the cumulative exposure level for a patient close to the source of the contamination pertained to Strategy E (upper diffusers on the sidewall supply and lower diffusers on the opposite sidewall return). Lateral ventilation strategies can provide significant guidance for ward operation to minimizing the airborne virus contamination. This study can provide a reference for sustainable buildings to construct a healthy indoor environment.

Indexed as

Cross-infectionExposure controlParticulate matterSide return air distributionVentilation performance

Identifiers

PMID34189016
PMCPMC8222082
OpenAlexW3174546341

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.