ArticleProceedings of SPIE--the International Society for Optical Engineering2017

Deformable Known Component Model-Based Reconstruction for Coronary CT Angiography.

X Zhang, S Tilley, S Xu, A Mathews, E R McVeigh, J W Stayman

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 54% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

X ZhangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205.
S TilleyDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205.
S XuDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205.
A MathewsDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205.
E R McVeighDepartment of Bioengineering, Medicine, Radiology, UC San Diego, La Jolla, CA USA 92093.
J W StaymanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205.
Johns Hopkins University · USUniversity of California, San Diego · US

Funding

Incorporating Prior Knowledge of Surgical Devices in CBCT-Guided InterventionsR21EB014964 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI STAYMAN, JOSEPH WEBSTER · 2013 to 2014
$439k
NIBIB NIH HHS R21 EB014964
6 · The paper itself

Abstract

purposeAtherosclerosis detection remains challenging in coronary CT angiography for patients with cardiac implants. Pacing electrodes of a pacemaker or lead components of a defibrillator can create substantial blooming and streak artifacts in the heart region, severely hindering the visualization of a plaque of interest. We present a novel reconstruction method that incorporates a deformable model for metal leads to eliminate metal artifacts and improve anatomy visualization even near the boundary of the component.

methodsThe proposed reconstruction method, referred as STF-dKCR, includes a novel parameterization of the component that integrates deformation, a 3D-2D preregistration process that estimates component shape and position, and a polyenergetic forward model for x-ray propagation through the component where the spectral properties are jointly estimated. The methodology was tested on physical data of a cardiac phantom acquired on a CBCT testbench. The phantom included a simulated vessel, a metal wire emulating a pacing lead, and a small Teflon sphere attached to the vessel wall, mimicking a calcified plaque. The proposed method was also compared to the traditional FBP reconstruction and an interpolation-based metal correction method (FBP-MAR).

resultsMetal artifacts presented in standard FBP reconstruction were significantly reduced in both FBP-MAR and STF-dKCR, yet only the STF-dKCR approach significantly improved the visibility of the small Teflon target (within 2 mm of the metal wire). The attenuation of the Teflon bead improved to 0.0481 mm

conclusionThe proposed method has the potential to improve plaque visualization in coronary CT angiography in the presence of wire-shaped metal components.

Indexed as

CT reconstructionimplant imagingmetal artifact reductionpenalized-likelihood estimation

Identifiers

PMID34188348
PMCPMC8238475
OpenAlexW2591932897

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390