Evidence map›Paper›PMID 34188088›Full record

ArticleScientific reports2021

Trans-obturator cable fixation of open book pelvic injuries.

Martin C Jordan, Veronika Jäckle, Sebastian Scheidt, Fabian Gilbert, Stefanie Hölscher-Doht, Süleyman Ergün, Rainer H Meffert, Timo M Heintel

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Transobturator-cable-fixation in pelvic ring injuries with symphyseal disruption - a last resort?European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Martin C JordanDepartment of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany. Jordan_M@ukw.de.ORCID 0000-0003-4356-0676
Veronika JäckleDepartment of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany.
Sebastian ScheidtDepartment of Orthopaedic Surgery, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
Fabian GilbertDepartment of Orthopedics, Physical Medicine and Rehabilitation, University Hospital LMU München, Marchioninistr. 15, 81377, München, Germany.
Stefanie Hölscher-DohtDepartment of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany.
Süleyman ErgünInstitute of Anatomy, Julius-Maximilians-University Würzburg, Koellikerstraße 6, 97070, Würzburg, Germany.
Rainer H MeffertDepartment of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany.
Timo M HeintelDepartment of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany.
Universitätsklinikum Würzburg · DELMU Klinikum · DEUniversity Hospital Bonn · DEUniversity of Würzburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Operative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications.

Indexed as

Bone PlatesFracture Fixation, InternalPelvic BonesPubic SymphysisFractures, BoneHumans

Identifiers

PMID34188088
PMCPMC8241833
OpenAlexW3176255896

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.