Evidence map›Paper›PMID 34184362›Full record

ArticleJournal of magnetic resonance imaging : JMRI2022

Improved Brain MR Imaging from a Compact, Lightweight 3T Scanner with High-Performance Gradients.

Emanuele Camerucci, Norbert G Campeau, Joshua D Trzasko, Erin M Gray, Matt A Bernstein, Petrice M Cogswell, Yunhong Shu, Thomas K Foo, John Huston

Abstract read
In one paragraph

Article in Journal of magnetic resonance imaging : JMRI, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Emanuele CamerucciDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.ORCID 0000-0002-5510-9834
Norbert G CampeauDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Joshua D TrzaskoDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Erin M GrayDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Matt A BernsteinDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.ORCID 0000-0003-3770-0441
Petrice M CogswellDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.ORCID 0000-0002-8128-4476
Yunhong ShuDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Thomas K FooGE Research, Niskayuna, New York, USA.
John HustonDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.

Funding

High-performance compact 3T MRI: Technical optimization for advanced brain imagingU01EB024450 · NIBIB · MAYO CLINIC ROCHESTER · PI BERNSTEIN, MATTHEW A., FOO, THOMAS K · 2017 to 2021
$5.3M
NIBIB NIH HHS U01 EB024450
6 · The paper itself

Abstract

backgroundA low-cryogen, compact  3T (C3T) MRI scanner with high-performance gradients capable of simultaneously achieving 80 mT/m gradient amplitude and 700 T/m/second slew rate has been in use to study research patients since March 2016 but has not been implemented in the clinical practice. PURPOSE: To compare head MRI examinations obtained with the C3T system and a conventional whole-body  3T (WB3T) scanner in seven parameters across five commonly used brain imaging sequences. STUDY TYPE: Prospective. SUBJECTS: Thirty patients with a clinically indicated head MRI. SEQUENCE: 3T; T1 FLAIR, T1 MP-RAGE, 3D T2 FLAIR, T2 FSE, and DWI. ASSESSMENT: All patients tolerated the scans well. Three board-certified neuroradiologists scored the comparative quality of C3T and WB3T images in blinded fashion using a five-point Likert scale in terms of: signal-to-noise ratio, lesion conspicuity, motion artifact, gray/white matter contrast, cerebellar folia, susceptibility artifact, and overall quality. STATISTICAL TEST: Left-sided, right-sided, and two-sided Wilcoxon signed rank test; Fisher's method. A P value <0.05 was considered statistically significant.

resultsThe C3T system performed better than the WB3T in virtually all comparisons, except for motion artifacts for the T1 FLAIR and T1 MP-RAGE sequences, where the WB3T system was deemed better. When combining all sequences together, the C3T system outperformed the WB3T system in all image quality parameters evaluated, except for motion artifact (P = 0.13). DATA

conclusionThe C3T scanner provided better overall image quality for all sequences, and performed better in all individual categories, except for motion artifact on the T1 FLAIR and T1 MP-RAGE. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.

Indexed as

BrainMagnetic Resonance ImagingArtifactsGray MatterHumansProspective Studies3TbrainMRI

Identifiers

PMID34184362
PMCPMC8806246

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.