ArticleBMC ophthalmology2021
Correlation between intraocular pressure reduction and anterior chamber aqueous flare after micropulse transscleral cyclophotocoagulation.
Article in BMC ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 8 citations in OpenAlex.
- Inflammation and patient satisfaction in micropulse versus continuous wave transscleral cyclophotocoagulation.The British journal of ophthalmology · 2025Trial
- Risk factors for tube exposure following Baerveldt glaucoma implantation and overlying tissue thickness assessed by anterior segment optical coherence tomography.Japanese journal of ophthalmology · 2026Article
- Correlation between mid-term intraocular pressure and aqueous flare value in micropulse transscleral cyclophotocoagulation: a retrospective observational study.BMC ophthalmology · 2026Observational
- Comparison of treatment outcomes between slow coagulation transscleral cyclophotocoagulation and micropulse transscleral laser treatment.Scientific reports · 2024Article
- Multi-Characteristic Opsin Therapy to Functionalize Retina, Attenuate Retinal Degeneration, and Restore Vision in Mouse Models of Retinitis Pigmentosa.Translational vision science & technology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMicropulse transscleral cyclophotocoagulation (MP-CPC) is a technique that has been approved in recent years to treat glaucoma. MP-CPC causes anterior chamber inflammation; a relationship with reduced intraocular pressure (IOP) has not been reported. Therefore, we analyzed the correlation between IOP and anterior chamber aqueous flare after MP-CPC.
methodsThis retrospective study included 37 eyes of 37 patients who underwent MP-CPC between November 2018 and October 2020. IOP and flare values were measured at 1, 4, and 12 weeks after MP-CPC. Correlations were assessed between the percentage IOP reduction and flare elevation by calculating Spearman's rank correlation coefficient.
resultsThe percentage IOP reduction at 1 week after surgery was correlated with the flare elevation at 1 week after surgery (ρ = 0.47, P = 0.006). The percentage IOP reduction at 12 weeks after surgery was correlated with the flare elevation at 4 weeks after surgery (ρ = 0.53, P = 0.006).
conclusionsA short-term correlation was implied between reduced IOP and flare elevation after MP-CPC.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials