Evidence map›Paper›PMID 34182931›Full record

ArticleBMC cardiovascular disorders2021

Application of three-dimensional transesophageal echocardiography in preoperative evaluation of transcatheter aortic valve replacement.

Peng Ding, Chennian Xu, Yang Liu, Xin Meng, Ping Jin, Jiayou Tang, Lanlan Li, Yanyan Ma, Jian Yang

Registry-linked trialOpen access · goldAbstract readComparative Study
In one paragraph

Article in BMC cardiovascular disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02917980 (Multicenter Registry Study of Surgery and Transcatheter Intervention for Structural Heart Diseases), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02917980 completednot on this map

Multicenter Registry Study of Surgery and Transcatheter Intervention for Structural Heart Diseases

Typeobservational_patient_registrySponsorXijing HospitalRan2016 to 2022Enrolled883ConditionsData Collecting and Analyzing of Different Treatment of Structural Heart Diseases
3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Peng DingDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127. Changle West Rd, Xi'an, 710032, China.
Chennian XuDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127. Changle West Rd, Xi'an, 710032, China.
Yang LiuDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127. Changle West Rd, Xi'an, 710032, China. liuyangxijing@126.com.
Xin MengDepartment of Ultrasound Medicine, Xijing Hospital, Air Force Medical University, Xi'an, China.
Ping JinDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127. Changle West Rd, Xi'an, 710032, China.
Jiayou TangDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127. Changle West Rd, Xi'an, 710032, China.
Lanlan LiDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127. Changle West Rd, Xi'an, 710032, China.
Yanyan MaDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127. Changle West Rd, Xi'an, 710032, China.
Jian YangDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, 127. Changle West Rd, Xi'an, 710032, China. yangjian1212@hotmail.com.ORCID 0000-0003-2059-1912
Xijing Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOur goal was to determine the accuracy of 3-dimensional transesophageal echocardiography (3D-TEE) compared with that of computed tomography (CT) in the preoperative evaluation for transcatheter aortic valve replacement (TAVR) when the errors caused by inconsistent software and method have been eliminated and the representativeness of the sample has been improved. We also investigated the influence of aortic root calcification on the accuracy of 3D-TEE in aortic annulus evaluations.

methodsPart I: 45 of 233 patients who underwent TAVR in the department of cardiovascular surgery at the Xijing hospital from January 2016 to August 2019 were studied retrospectively. Materialise Mimics software and the multiplanar reconstruction method were used for evaluation, based on 3D-TEE and CT. The annulus area-derived diameter, the annulus perimeter-derived diameter (Dp), the annulus mean diameter, the left ventricular outflow tract Dp diameter, the sinotubular junction (STJ) diameter-Dp, and the aortic sinus diameter were compared and analyzed. Part II: 31 of 233 patients whose 3D-TEE and CT data were well preserved and in the required format were included. HU450 and HU850 were used as indicators to measure the severity of calcification. The Spearman rank correlation and Linear regression were used to analyze the correlation between aortic root calcification and the accuracy of 3D-TEE in aortic annulus measurement.

resultsThe measurement results based on 3D-TEE were significantly lower than those obtained using CT (P < 0.05), except for the STJ diameter-Dp in diastole (P = 0.11). The correlation coefficient of the two groups was 0.699-0.954 (P < 0.01), which also indicated a significant correlation between the two groups. A Bland-Altman plot showed that the ordinate values were mostly within the 95% consistency limit; the consistency of the two groups was good. By establishing the linear regression equation, the two groups can be inferred from each other. The Spearman rank correlation analysis and the Linear regression analysis showed that the influence of aortic calcification on the accuracy of the 3D-TEE annulus evaluation was limited.

conclusionsAlthough an evaluation based on 3D-TEE underestimated the results, we can deduce CT results from 3D-TEE because the two methods exhibit considerable correlation and consistency.

trial registrationName: Surgery and Transcatheter Intervention for Structural Heart Diseases. Number: NCT02917980. URL: https://clinicaltrials.gov/ct2/results?term=NCT02917980 .

Indexed as

Echocardiography, Three-DimensionalEchocardiography, TransesophagealTranscatheter Aortic Valve ReplacementAgedAortic ValveAortic Valve InsufficiencyAortic Valve StenosisCalcinosisClinical Decision-MakingFemaleHumansMaleMiddle AgedPredictive Value of TestsReproducibility of ResultsRetrospective StudiesAortic root sizingAortic valve calcificationComputed tomographyThree-dimensional transesophageal echocardiographyTranscatheter aortic valve replacement

Identifiers

PMID34182931
PMCPMC8237423
OpenAlexW3174095187

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.