Evidence map›Paper›PMID 34181192›Full record

ArticleInternational ophthalmology2021

Impact of age, sex and refractive error on conjunctival and Tenon's capsule thickness dimensions by swept-source optical coherence tomography in a large population.

José Ignacio Fernández-Vigo, Hang Shi, Bárbara Burgos-Blasco, Lucía De-Pablo-Gómez-de-Liaño, Ignacio Almorín-Fernández-Vigo, Bachar Kudsieh, José Ángel Fernández-Vigo

Abstract read
PubMed Publisher
In one paragraph

Article in International ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

José Ignacio Fernández-VigoDepartment of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Zurbano 71 Street, 28010, Madrid, Spain. jfvigo@hotmail.com.ORCID http://orcid.org/0000-0001-8745-3464
Hang ShiDepartment of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Zurbano 71 Street, 28010, Madrid, Spain.
Bárbara Burgos-BlascoDepartment of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Zurbano 71 Street, 28010, Madrid, Spain.
Lucía De-Pablo-Gómez-de-LiañoCentro Internacional de Oftalmología Avanzada, Madrid, Spain.
Ignacio Almorín-Fernández-VigoCentro Internacional de Oftalmología Avanzada, Badajoz, Spain.
Bachar KudsiehCentro Internacional de Oftalmología Avanzada, Madrid, Spain.
José Ángel Fernández-VigoCentro Internacional de Oftalmología Avanzada, Madrid, Spain.
Instituto de Investigación Sanitaria del Hospital Clínico San Carlos · ESCentro de Implantología Cirugía Oral y Maxilofacial · ESHospital Universitario Puerta de Hierro Majadahonda · ESResearch Institute Hospital 12 de Octubre · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate conjunctival and Tenon's capsule thickness (CTT) in a large healthy population using swept-source optical coherence tomography (SS-OCT), investigating the impact of age, sex and refractive error.

methods630 healthy participants underwent a complete ophthalmological examination. CTT was manually measured in the temporal and nasal quadrants at 0, 1, 2 and 3 mm from the scleral spur using SS-OCT (CTT0, CTT1, CTT2 and CTT3, respectively). These dimensions were then assessed for associations in a multivariate regression model with age, sex, refractive error and anterior scleral thickness (AST). The reproducibility of the CTT measurements was determined in 30 individuals.

resultsCTT dimensions could be measured in 596 cases (94.6%); mean age was 42.6 ± 17.2 years (range 5-86). Mean CTT0 was 199.2 ± 33.8 and 192.9 ± 33.9 µm, mean CTT1 195.4 ± 38.0 µm and 199.9 ± 50.9 µm, mean CTT2 187.0 ± 38.4 and 194.8 ± 48.9 µm, and CTT3 180.5 ± 35.6 µm and 191.8 ± 43.7 µm, for the temporal and nasal quadrants, respectively. No difference in CTT was observed in the nasal versus temporal quadrant (p ≥ 0.106) except for the CTT0 and CTT3 (p = 0.001). Moderate correlation was observed between nasal and temporal CTT (R = 0.472, p < 0.001). In the multivariate model, no influence was observed by sex, refractive error and AST on CTT measurements (p ≥ 0.065). Negative association was observed between age and CTT (p < 0.005). The reproducibility was excellent (intraclass correlation coefficient ≥ 0.908).

conclusionsSS-OCT allows for in vivo CTT evaluation. Our data document a wide range of measurements, showing negative association between CTT and age.

Indexed as

Refractive ErrorsTomography, Optical CoherenceAdolescentAdultAgedAged, 80 and overChildChild, PreschoolHumansMiddle AgedReproducibility of ResultsScleraTenon CapsuleYoung AdultAgingAnterior scleral thicknessConjunctival and Tenon’s capsule thicknessEye anterior segmentOptical coherence tomography

Identifiers

PMID34181192
OpenAlexW3174447868

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked