Evidence map›Paper›PMID 34181119›Full record

ArticleMagma (New York, N.Y.)2021

Feasibility of accelerated 3D T1-weighted MRI using compressed sensing: application to quantitative volume measurements of human brain structures.

Uten Yarach, Suwit Saekho, Kawin Setsompop, Atita Suwannasak, Ratthaporn Boonsuth, Kittichai Wantanajittikul, Salita Angkurawaranon, Chaisiri Angkurawaranon, Prapatsorn Sangpin

Abstract read
PubMed Publisher
In one paragraph

Article in Magma (New York, N.Y.), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Uten YarachDepartment of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, 110 Intavaroros Rd. Sripoom, Chiang Mai, 50200, Thailand. uten.yarach@cmu.ac.th.ORCID http://orcid.org/0000-0002-5923-2864
Suwit SaekhoDepartment of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, 110 Intavaroros Rd. Sripoom, Chiang Mai, 50200, Thailand.
Kawin SetsompopDepartment of Radiology, Stanford University, Stanford, CA, USA.
Atita SuwannasakDepartment of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, 110 Intavaroros Rd. Sripoom, Chiang Mai, 50200, Thailand.
Ratthaporn BoonsuthDepartment of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, 110 Intavaroros Rd. Sripoom, Chiang Mai, 50200, Thailand.
Kittichai WantanajittikulDepartment of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, 110 Intavaroros Rd. Sripoom, Chiang Mai, 50200, Thailand.
Salita AngkurawaranonDepartment of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
Chaisiri AngkurawaranonDepartment of Family Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
Prapatsorn SangpinPhilips (Thailand) Ltd., Bangkok, Thailand.
Chiang Mai University · THStanford University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveScan time reduction is necessary for volumetric acquisitions to improve workflow productivity and to reduce motion artifacts during MRI procedures. We explored the possibility that Compressed Sensing-4 (CS-4) can be employed with 3D-turbo-field-echo T1-weighted (3D-TFE-T1W) sequence without compromising subcortical measurements on clinical 1.5 T MRI. MATERIALS AND

methodsThirty-three healthy volunteers (24 females, 9 males) underwent imaging scans on a 1.5 T MRI equipped with a 12-channel head coil. 3D-TFE-T1W for whole-brain coverage was performed with different acceleration factors, including SENSE-2, SENSE-4, CS-4. Freesurfer, FSL's FIRST, and volBrain packages were utilized for subcortical segmentation. All processed data were assessed using the Wilcoxon signed-rank test.

resultsThe results obtained from SENSE-2 were considered as references. For SENSE-4, the maximum signal-to-noise ratio (SNR) drop was detected in the Accumbens (51.96%). For CS-4, the maximum SNR drop was detected in the Amygdala (10.55%). Since the SNR drop in CS-4 is relatively small, the SNR in all of the subcortical volumes obtained from SENSE-2 and CS-4 are not statistically different (P > 0.05), and their Pearson's correlation coefficients are larger than 0.90. The maximum biases of SENSE-4 and CS-4 were found in the Thalamus with the mean of differences of 1.60 ml and 0.18 ml, respectively.

conclusionCS-4 provided sufficient quality of 3D-TFE-T1W images for 1.5 T MRI equipped with a 12-channel receiver coil. Subcortical volumes obtained from the CS-4 images are consistent among different post-processing packages.

Indexed as

BrainMagnetic Resonance ImagingFeasibility StudiesFemaleHumansImaging, Three-DimensionalMaleSignal-To-Noise Ratio3D-T1 weightedBrain volume measurementCompressed sensingMRIParallel imagingSubcortical structures

Identifiers

PMID34181119
OpenAlexW3127032205

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.