Dynamic cardiac PET motion correction using 3D normalized gradient fields in patients and phantom simulations.

Jonathon A Nye, Marina Piccinelli, Doyeon Hwang, Charles David Cooke, Jin Chul Paeng, Joo Myung Lee, Sang-Geon Cho, Russell Folks, Hee-Seung Bom, Bon-Kwon Koo and 1 more

Abstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Jonathon A NyeDepartment of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA.
Marina PiccinelliDepartment of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA.
Doyeon HwangDepartment of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, Korea.
Charles David CookeDepartment of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA.
Jin Chul PaengDepartment of Nuclear Medicine, Seoul National University Hospital, Seoul, Korea.
Joo Myung LeeSamsung Medical Center, Heart Vascular Stroke Institute, Seoul, Korea.
Sang-Geon ChoDepartment of Nuclear Medicine, Chonnam National University Hospital, Gwangju, Korea.
Russell FolksDepartment of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA.
Hee-Seung BomDepartment of Nuclear Medicine, Chonnam National University Hospital, Gwangju, Korea.
Bon-Kwon KooDepartment of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, Korea.
Ernest V GarciaDepartment of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA.

Funding

Quantification of myocardial blood flow using Dynamic PET/CTA fused imagery to determine physiological significance of specific coronary lesionsR01HL143350 · NHLBI · EMORY UNIVERSITY · PI PICCINELLI, MARINA · 2018 to 2021
$2.4M
NHLBI NIH HHS R01 HL143350
6 · The paper itself

Abstract

This work expands on the implementation of three-dimensional (3D) normalized gradient fields to correct for whole-body motion and cardiac creep in [N-13]-ammonia patient studies and evaluates its accuracy using a dynamic phantom simulation model.

methodsA full rigid-body algorithm was developed using 3D normalized gradient fields including a multi-resolution step and sampling off the voxel grid to reduce interpolation artifacts. Optimization was performed using a weighted similarity metric that accounts for opposing gradients between images of blood pool and perfused tissue without the need for segmentation. Forty-three retrospective dynamic [N-13]-ammonia PET/CT rest/adenosine-stress patient studies were motion corrected and the mean motion parameters plotted at each frame time point. Motion correction accuracy was assessed using a comprehensive dynamic XCAT simulation incorporating published physiologic parameters of the heart's trajectory following adenosine infusion as well as corrupted attenuation correction commonly observed in clinical studies. Accuracy of the algorithm was assessed objectively by comparing the errors between isosurfaces and centers of mass of the motion corrected XCAT simulations.

resultsIn the patient studies, the overall mean cranial-to-caudal translation was 7 mm at stress over the duration of the adenosine infusion. Noninvasive clinical measures of relative flow reserve and myocardial flow reserve were highly correlated with their invasive analogues. Motion correction accuracy assessed with the XCAT simulations showed an error of <1 mm in late perfusion frames that broadened gradually to <3 mm in earlier frames containing blood pool.

conclusionThis work demonstrates that patients undergoing [N-13]-ammonia dynamic PET/CT exhibit a large cranial-to-caudal translation related to cardiac creep primarily at stress and to a lesser extent at rest, which can be accurately corrected by optimizing their 3D normalized gradient fields. Our approach provides a solution to the challenging condition where the image intensity and its gradients are opposed without the need for segmentation and remains robust in the presence of PET-CT mismatch.

Indexed as

Positron-Emission TomographyPositron Emission Tomography Computed TomographyAlgorithmsArtifactsHumansImage Processing, Computer-AssistedMovementPhantoms, ImagingRetrospective Studiescardiac PETphantomsregistration

Identifiers

PMID34174095
PMCPMC8455441

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.