The electrocardiogram characteristics and pacing parameters of permanent left bundle branch pacing: a systematic review and meta-analysis.

Jia Gao, Bing-Hang Zhang, Nan Zhang, Meng Sun, Rui Wang

Abstract readMeta-AnalysisSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Left bundle branch area pacing in patients with baseline narrow, left, or right bundle branch block QRS patterns: insights into electrocardiographic and echocardiographic features.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jia Gao *Department of Physiology, Shanxi Medical University, Taiyuan, Shanxi, China.
Bing-Hang Zhang *The First Clinical Medical College, Shanxi Medical University, Taiyuan, Shanxi, China.
Nan ZhangDepartment of Cardiology, The First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China.
Meng SunDepartment of Cardiology, The First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China.
Rui WangDepartment of Cardiology, The First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China. w4639551@126.com.ORCID http://orcid.org/0000-0002-9340-6477

Funding

The Cultivation Project of Young and Middle-aged Academic Leaders of the First Hospital of Shanxi Medical University YD1609
6 · The paper itself

Abstract

purposeRecent advances in conduction system pacing have led to the use of left bundle branch pacing (LBBP), which has potential advantages over His bundle pacing (HBP). For example, LBBP engages the electrical activation through the left bundle branch, produces ventricular electrical synchrony, and avoids the weakness of HBP such as lead instability, higher threshold, and early battery depletion. This pacing modality has been considered an attractive mode to achieve normal physiological pacing. However, as a new technology, LBBP is still in the stage of clinical exploration and lacks adequate evaluation. This study aims to investigate the electrocardiogram characteristics, pacing parameters, the safety, and the effectiveness of LBBP.

methodsA computerized search of PubMed, Embase, and The Cochrane Library for the effects of LBBP was done. The baseline characteristics of patients, successful rate of implantation, capture threshold, R-wave amplitude, pacing impedance, QRS duration, and follow-up date were extracted and summarized.

resultsThirteen studies including 712 patients were included in this analysis. The overall successful rate for implantation was 92.9%. The main indications for LBBP were atrioventricular block (AVB), sinus node dysfunction (SND), atrial fibrillation (AF) with slow ventricular rate, and cardiac resynchronization therapy (CRT) candidates. For patients with QRS duration>120 ms, permanent LBBP resulted in narrower QRS duration compared to that before implantation (P = 0.05). QRS duration and capture threshold of LBBP remained stable during follow-up. Moreover, there was higher R-wave amplitude and lower pacing impedance at follow-up compared to those at implantation (P = 0.01 and P < 0.00001, respectively).

conclusionsPermanent LBBP has shown promising results for pacemaker-indicated patients in small observational studies. Good electrical synchronization, high success rates, and stable pacemaker lead parameters suggested significant advantages of LBBP in physiological pacing. Randomized controlled trials are needed to assess the efficacy of LBBP in patients.