A Single-opening&closing Valve Tester for Direct Measurement of Closing Volume of the Heart Valve.

Hao Wang, Zhan Cui, Zhongxi Zhou, Zhaoming He

Abstract read
PubMed Publisher
In one paragraph

Article in Cardiovascular engineering and technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Hao WangResearch Center of Fluid Machinery Engineering & Technology, Jiangsu University, Zhenjiang, 212013, Jiangsu Province, People's Republic of China.
Zhan CuiResearch Center of Fluid Machinery Engineering & Technology, Jiangsu University, Zhenjiang, 212013, Jiangsu Province, People's Republic of China.
Zhongxi ZhouResearch Center of Fluid Machinery Engineering & Technology, Jiangsu University, Zhenjiang, 212013, Jiangsu Province, People's Republic of China.
Zhaoming HeDepartment of Mechanical Engineering, Texas Tech University, 2703 7th Street, PO Box 41021, Lubbock, TX, 79409-1021, USA. zhaoming.he@ttu.edu.ORCID 0000-0003-2182-3359
Jiangsu University · CNTexas Tech University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe objective of this study was to develop a novel single opening&closing pulsatile flow in-vitro valve tester for direct measurement of closing volume of the heart valve.

methodsA single opening&closing valve tester was composed of a piston pump, valve mounting chamber, reservoir, measurement and control system. The piston pump was used to drive a valve to open and close with dictated flow which comprised three phases of accelerated, constant, and decelerated flow with six slopes. A high speed camera was used to record valve opening and closing images. Two pressure transducers across the tested valve were used to capture the ending time of valve closing which was verified by the high-speed photography. The closing time was measured and closing volume was calculated with a piston displacement volume during valve closing. A tilting disc valve and porcine mitral valve were tested.

resultsThere was a big difference in flowrate between the Transonic flowmeter and piston pump. The heart valve opened and closed under the dictated flow driven by the piston pump. The transvalvular pressure was minor during valve opening and then increased sharply during valve closing. The closing time varied approximately linearly with the slope of the decelerated flow and was comparable between the two methods by the transvalvular pressure and high-speed photography. The closing volumes did not change much with the slope of the decelerated flow and were 7.0 ± 1.0 and 14.0 ± 1.5 mL for the tilting disc valve and mitral valve, respectively.

conclusionPulsatile flow is challenging to the flowmeter. A novel single opening&closing pulsatile flow in-vitro valve tester for the heart valve has successfully been developed and can be used to simulate and evaluate the opening and closing hemodynamics of the heart valve. The tester can be used to measure valve closing volume and time accurately with a standardized testing protocol free from effect of other components such as the resistance, compliance units and auxiliary valve in the continuous pulsatile flow valve tester.

Indexed as

Heart Valve ProsthesisAnimalsClosing VolumeHemodynamicsMitral ValveProsthesis DesignPulsatile FlowSwineHeart valveRegurgitationReplacement and repairStandardized pulsatile tester

Identifiers

PMID34173164
OpenAlexW3176509064

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.