Evidence map›Paper›PMID 34168907›Full record

ArticleBiomedical optics express2021

Spatiotemporal monitoring of changes in oxy/deoxy-hemoglobin concentration and blood pulsation on human skin using smartphone-enabled remote multispectral photoplethysmography.

Qinghua He, Zhiyuan Sun, Yuandong Li, Wendy Wang, Ruikang K Wang

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Choroidal thinning can be assessed through facial video analysis.Quantitative imaging in medicine and surgery · 2025
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Qinghua HeDepartment of Bioengineering, University of Washington, Seattle, WA 98105, USA.ORCID https://orcid.org/0000-0002-7960-6683
Zhiyuan SunDepartment of Bioengineering, University of Washington, Seattle, WA 98105, USA.
Yuandong LiDepartment of Bioengineering, University of Washington, Seattle, WA 98105, USA.ORCID https://orcid.org/0000-0003-3544-1175
Wendy WangDepartment of Bioengineering, University of Washington, Seattle, WA 98105, USA.
Ruikang K WangDepartment of Bioengineering, University of Washington, Seattle, WA 98105, USA.ORCID https://orcid.org/0000-0001-5169-8822
University of Washington · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We propose a smartphone-enabled remote multispectral photoplethysmography (SP-rmPPG) system and method to realize spatiotemporal monitoring of perfusion changes and pulsations of the oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) information of the effective blood volume within light interrogated skin tissue beds. The system is implemented on an unmodified smartphone utilizing its built-in camera and flashlight to acquire videos of the skin reflectance. The SP-rmPPG method converts the RGB video into multispectral cubes, upon which to decouple the dynamic changes in HbO2 and Hb information using a modified Beer-Lambert law and the selective wavelength bands of 500 nm and 650 nm. Blood pulsation amplitudes are then obtained by applying a window-based lock-in amplification on the derived spatiotemporal changes in HbO2 or Hb signals. To demonstrate the feasibility of proposed method, we conduct two experiments on the skin tissue beds that are conditioned by occlusive maneuver of supplying arteries: one using the popular blood cuff pressure maneuver on the upper arm, and another artificially inducing a transient ischemic condition on the facial skin tissue beds by finger pressing on the supplying external carotid artery. The cuff experiment shows that the measured dynamic information of HbO2 and Hb in the downstream agrees well with the parallel measurements of oxygenation saturation given by the standard pulse oximeter. We also observe the expected imbalance of spatiotemporal changes in the HbO2 and Hb between the right and left cheeks when the transient ischemic condition is induced in the one side of facial skin tissue beds. The results from the two experiments sufficiently demonstrate the feasibility of the proposed method to monitor the spatiotemporal changes in the skin hemodynamics, including blood oxygenation and pulsation amplitudes. Considering the ever-growing accessibility and affordability of the smartphone to the general public, the proposed strategy promises the early screening of vascular diseases and improving general public health particularly in rural areas with low resource settings.

Identifiers

PMID34168907
PMCPMC8194624
OpenAlexW3156142934

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.