Evidence map›Paper›PMID 34168773›Full record

ArticleChemical science2021

Direct observation of ion emission from charged aqueous nanodrops: effects on gaseous macromolecular charging.

Conner C Harper, Daniel D Brauer, Matthew B Francis, Evan R Williams

Open access · diamondAbstract read
In one paragraph

Article in Chemical science, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
4.5field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 51 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Single particle charge detection mass spectrometry enables molecular characterization of lipid nanoparticles and mRNA packaging.Journal of controlled release : official journal of the Controlled Release Society · 2025
    Article
  7. Article
  8. Article
  9. A Source of the MysteriousACS central science · 2025
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Conner C HarperDepartment of Chemistry, University of California Berkeley California 94720-1460 USA erw@berkeley.edu.ORCID https://orcid.org/0000-0002-6225-508X
Daniel D BrauerDepartment of Chemistry, University of California Berkeley California 94720-1460 USA erw@berkeley.edu.
Matthew B FrancisDepartment of Chemistry, University of California Berkeley California 94720-1460 USA erw@berkeley.edu.
Evan R WilliamsDepartment of Chemistry, University of California Berkeley California 94720-1460 USA erw@berkeley.edu.ORCID https://orcid.org/0000-0002-1733-3018
Berkeley College · US

Funding

User Training and OutreachP30GM124169 · NIGMS · UNIVERSITY OF CALIF-LAWRENC BERKELEY LAB · PI PAUL David ADAMS, Gregory L Hura · 2017 to 2026
$28.6M
A Pixel Array Detector System for Small Angle X-ray ScatteringS10OD018483 · OD · UNIVERSITY OF CALIF-LAWRENC BERKELEY LAB · PI CLASSEN, SCOTT · 2014 to 2014
$998k
NIGMS NIH HHS P30 GM124169NIH HHS S10 OD018483
6 · The paper itself

Abstract

Mechanistic information about how gaseous ions are formed from charged droplets has been difficult to establish because direct observation of nanodrops in a size range relevant to gaseous macromolecular ion formation by optical or traditional mass spectrometry methods is challenging owing to their small size and heterogeneity. Here, the mass and charge of individual aqueous nanodrops between 1-10 MDa (15-32 nm diameter) with ∼50-300 charges are dynamically monitored for 1 s using charge detection mass spectrometry. Discrete losses of minimally solvated singly charged ions occur, marking the first direct observation of ion emission from aqueous nanodrops in late stages of droplet evaporation relevant to macromolecular ion formation in native mass spectrometry. Nanodrop charge depends on the identity of constituent ions, with pure water nanodrops charged slightly above the Rayleigh limit and aqueous solutions containing alkali metal ions charged progressively below the Rayleigh limit with increasing cation size. MS2 capsid ions (∼3.5 MDa; ∼27 nm diameter) are more highly charged from aqueous ammonium acetate than from its biochemically preferred, 100 mM NaCl/10 mM Na phosphate solution, consistent with ion emission reducing the nanodrop and resulting capsid charge. The extent of charging indicates that the capsid partially collapses inside the nanodrops prior to the charging and formation of the dehydrated gaseous ions. These results demonstrate that ion emission can affect macromolecular charging and that conformational changes to macromolecular structure can occur in nanodrops prior to the formation of naked gaseous ions.

Identifiers

PMID34168773
PMCPMC8179642
OpenAlexW3133973391

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.