Evidence map›Paper›PMID 34168470›Full record

ArticleClinicoEconomics and outcomes research : CEOR2021

Economic Analysis of Leak Complications in Anastomoses Performed with Powered versus Manual Circular Staplers in Left-Sided Colorectal Resections: A US-Based Cost Analysis.

Esther Pollack, Stephen Johnston, William J Petraiuolo, Sanjoy Roy, Thibaut Galvain

Open access · goldAbstract read
In one paragraph

Article in ClinicoEconomics and outcomes research : CEOR, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 2 pooled it
1.4field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 2 syntheses or guidelines pooled it, 20 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Observational
  6. Article
  7. Real-life introduction of powered circular stapler for esophagogastric anastomosis: cohort and propensity matched score study.Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus · 2023
    Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Esther PollackFranchise Health Economics and Market Access, Ethicon, Blue Ash, OH, USA.
Stephen JohnstonMedical Device Epidemiology and Real-World Data Sciences, Johnson & Johnson, New Brunswick, NJ, USA.
William J PetraiuoloMedical Affairs, Ethicon, Cincinnati, OH, USA.
Sanjoy RoyFranchise Health Economics and Market Access, Ethicon, Blue Ash, OH, USA.
Thibaut GalvainGlobal Health Economics, Johnson and Johnson Medical Devices, New Brunswick, NJ, USA.
Johnson & Johnson (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo estimate the cost impact of using the ECHELON CIRCULAR™ Powered Stapler (ECP) compared with manual circular staplers (standard of care, SOC) among patients undergoing colectomy procedures that involve left-sided anastomosis.

methodsA US hospital-based budget impact model was developed to estimate the impact of ECP in reducing the surgical complication of anastomotic leak. The incremental acquisition cost of ECP vs SOC was compared to the net potential savings from reduced complication costs. The model was based on complication rates from a recently published matching-adjusted indirect comparison (MAIC) that compared clinical and healthcare utilization outcomes of patients using ECP with those of a propensity score-matched retrospective SOC control cohort from a real-world clinical practice population. The model assessed total cost, average length of stay (LOS), proportion of patients with a non-home discharge, and all-cause readmission. Deterministic (DSA) and probabilistic sensitivity analyses (PSA) were conducted to evaluate the robustness of the model assumptions and inputs.

resultsDespite a higher device cost of $412 for ECP compared with $298 for a manual stapler, annual savings due to avoided complications with ECP was $53,987 for anastomotic leak, assuming 100 procedures per year with each type of circular stapler. ECP also helped to avoid 27 LOS days, 0.38 readmissions and 0.22 non-home discharges. Sensitivity analyses around potential drivers of costs established the robustness of economic savings with the use of ECP - with annual savings being most impacted by the probability of anastomotic leak complication in the DSA.

conclusionThis model demonstrates that among patients undergoing left-sided colectomy procedures, the incremental cost of using the ECHELON CIRCULAR™ Powered Stapler instead of a manual circular stapler was offset by the savings from lowered incidence and cost of management of anastomotic leaks in the hospital setting.

Indexed as

anastomotic leakcircular staplercolectomycostsoutcomes

Identifiers

PMID34168470
PMCPMC8217739
OpenAlexW3168662478

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked