Evidence map›Paper›PMID 34167482›Full record

ArticleBMC anesthesiology2021

Assessing the accuracy of ultrasound measurements of tracheal diameter: an in vitro experimental study.

Ran Ye, Feifei Cai, Chengnan Guo, Xiaocheng Zhang, Dan Yan, Chengshui Chen, Bin Chen

Open access · goldAbstract read
In one paragraph

Article in BMC anesthesiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Ran Ye *Department of Ultrasonography, The second Affiliated Hospital and Yuying children's Hospital of Wenzhou Medical University, Wenzhou, 325006, Zhejiang, China.
Feifei Cai *Department of Ultrasonography, Lucheng People's Hospital of Wenzhou, Wenzhou, 325006, Zhejiang, China.
Chengnan GuoDepartment of Preventive Medicine, School of Public Health & Management, Wenzhou Medical University, Wenzhou, 325006, Zhejiang, China.
Xiaocheng ZhangKey Laboratory of Interventional Pulmonology of Zhejiang Province, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, 325006, Zhejiang, China.
Dan YanDepartment of Pulmonary and Critical Care Medicine, Jinhua Municipal Central Hospital, Jinhua, 321000, Zhejiang, China.
Chengshui ChenKey Laboratory of Interventional Pulmonology of Zhejiang Province, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, 325006, Zhejiang, China. ccswenz@163.com.ORCID 0000-0001-7365-779X
Bin ChenDepartment of Ultrasonography, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, 325006, Zhejiang, China. doctorchbe@126.com.
Wenzhou Medical University · CNJinhua Central Hospital · CNWenzhou City People's Hospital · CN

Funding

the National Key Research and Development Program of China 2016YFC1304000
6 · The paper itself

Abstract

backgroundRecent studies indicate that ultrasound can detect changes in tracheal diameter during endotracheal tube (ETT) cuff inflation. We sought to assess the accuracy of ultrasound measurement of tracheal diameter, and to determine the relationship between tracheal wall pressure (TWP), cuff inflation volume (CIV), and the degree of tracheal deformation.

methodsOur study comprised two parts: the first included 45 porcine tracheas, the second 41 porcine tracheas. Each trachea was intubated with a cuffed ETT, which was connected to an injector and the manometer via a three-way tap. The cuff was inflated and the cuff pressure recorded before and after intubation. The tracheal diameter was measured using ultrasound. This included three separate measurements: outer transverse diameter (OTD), internal transverse diameter (ITD), and anterior tracheal wall thicknesses (ATWT). A precision electronic Vernier caliper was also used to measure tracheal diameter. We calculated TWP and the percentage change of tracheal diameter. The Bland-Altman method, linear regression, and locally weighted regression (LOESS) were used to analyze the data.

resultsThere were strong correlation and agreement for OTD (r = 0.97, P < 0.001) and ITD (r = 0.90, P < 0.001) as measured by ultrasound and by precision electronic Vernier caliper, but a poor correlation for ATWT (r = 0.58, P < 0.001). There was a strong correlation between the percentage change of OTD (OTD%, r = 0.75, P < 0.001) and CIV, the percentage change of ITD (ITD%, r = 0.77, P < 0.001) and CIV, TWP (r = 0.75, P < 0.001) and CIV. And a strong correlation was also found between TWP and OTD% (r = 0.84, P < 0.001), TWP and ITD% (r = 0.84, P < 0.001).

conclusionsUse of ultrasound to measure OTD and ITD is accurate, but is less accurate for ATWT. There is a close correlation between OTD%, ITD%, CIV and TWP.

Indexed as

AnimalsEquipment DesignIntubation, IntratrachealPressureSwineTracheaUltrasonographyCuff inflation volumeEndotracheal tubeTracheal diameterTracheal wall pressureUltrasound

Identifiers

PMID34167482
PMCPMC8223278
OpenAlexW3176313780

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.