Evidence map›Paper›PMID 34164335›Full record

ArticleFrontiers in oncology2021

Training and Validation of Deep Learning-Based Auto-Segmentation Models for Lung Stereotactic Ablative Radiotherapy Using Retrospective Radiotherapy Planning Contours.

Jordan Wong, Vicky Huang, Joshua A Giambattista, Tony Teke, Carter Kolbeck, Jonathan Giambattista, Siavash Atrchian

Abstract read
In one paragraph

Article in Frontiers in oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Article
  2. Review
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Deep learning for autosegmentation for radiotherapy treatment planning: State-of-the-art and novel perspectives.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025
    Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jordan WongRadiation Oncology, British Columbia Cancer - Vancouver, Vancouver, BC, Canada.
Vicky HuangMedical Physics, British Columbia Cancer - Fraser Valley, Surrey, BC, Canada.
Joshua A GiambattistaRadiation Oncology, Saskatchewan Cancer Agency, Regina, SK, Canada.
Tony TekeMedical Physics/Radiation Oncology, British Columbia Cancer - Kelowna, Kelowna, BC, Canada.
Carter KolbeckLimbus AI Inc, Regina, SK, Canada.
Jonathan GiambattistaLimbus AI Inc, Regina, SK, Canada.
Siavash AtrchianMedical Physics/Radiation Oncology, British Columbia Cancer - Kelowna, Kelowna, BC, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDeep learning-based auto-segmented contour (DC) models require high quality data for their development, and previous studies have typically used prospectively produced contours, which can be resource intensive and time consuming to obtain. The aim of this study was to investigate the feasibility of using retrospective peer-reviewed radiotherapy planning contours in the training and evaluation of DC models for lung stereotactic ablative radiotherapy (SABR).

methodsUsing commercial deep learning-based auto-segmentation software, DC models for lung SABR organs at risk (OAR) and gross tumor volume (GTV) were trained using a deep convolutional neural network and a median of 105 contours per structure model obtained from 160 publicly available CT scans and 50 peer-reviewed SABR planning 4D-CT scans from center A. DCs were generated for 50 additional planning CT scans from center A and 50 from center B, and compared with the clinical contours (CC) using the Dice Similarity Coefficient (DSC) and 95% Hausdorff distance (HD).

resultsComparing DCs to CCs, the mean DSC and 95% HD were 0.93 and 2.85mm for aorta, 0.81 and 3.32mm for esophagus, 0.95 and 5.09mm for heart, 0.98 and 2.99mm for bilateral lung, 0.52 and 7.08mm for bilateral brachial plexus, 0.82 and 4.23mm for proximal bronchial tree, 0.90 and 1.62mm for spinal cord, 0.91 and 2.27mm for trachea, and 0.71 and 5.23mm for GTV. DC to CC comparisons of center A and center B were similar for all OAR structures.

conclusionsThe DCs developed with retrospective peer-reviewed treatment contours approximated CCs for the majority of OARs, including on an external dataset. DCs for structures with more variability tended to be less accurate and likely require using a larger number of training cases or novel training approaches to improve performance. Developing DC models from existing radiotherapy planning contours appears feasible and warrants further clinical workflow testing.

Indexed as

computer-assistmachine learningradiotherapyradiotherapy planstereotactic ablative body radiation

Identifiers

PMID34164335
PMCPMC8215371

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.