Evidence map›Paper›PMID 34161355›Full record

ArticlePloS one2021

Comparative performance and cycle threshold values of 10 nucleic acid amplification tests for SARS-CoV-2 on clinical samples.

Miyuki Mizoguchi, Sohei Harada, Koh Okamoto, Yoshimi Higurashi, Mahoko Ikeda, Kyoji Moriya

Erratum issuedOpen access · goldAbstract readComparative Study
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
1.0field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Miyuki MizoguchiDepartment of Infection Control and Prevention, The University of Tokyo Hospital, Tokyo, Japan.
Sohei HaradaDepartment of Infection Control and Prevention, The University of Tokyo Hospital, Tokyo, Japan.ORCID 0000-0003-3073-6564
Koh OkamotoDepartment of Infectious Diseases, The University of Tokyo Hospital, Tokyo, Japan.ORCID 0000-0002-4072-9096
Yoshimi HigurashiDepartment of Infection Control and Prevention, The University of Tokyo Hospital, Tokyo, Japan.
Mahoko IkedaDepartment of Infection Control and Prevention, The University of Tokyo Hospital, Tokyo, Japan.
Kyoji MoriyaDepartment of Infection Control and Prevention, The University of Tokyo Hospital, Tokyo, Japan.
University of Tokyo Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA number of nucleic acid amplification tests (NAATs) for SARS-CoV-2 with different reagents have been approved for clinical use in Japan. These include research kits approved under emergency use authorization through simplified process to stabilize the supply of the reagents. Although these research kits have been increasingly used in clinical practice, limited data is available for the diagnostic performance in clinical settings.

methodsWe compared sensitivity, specificity, and cycle threshold (Ct) values obtained by NAATs using 10 kits approved in Japan including eight kits those receiving emergency use authorization using 69 frozen-stored clinical samples including 23 positive samples with various Ct values and 46 negative samples.

resultsViral copy number of the frozen-stored samples determined with LightMix E-gene test ranged from 0.6 to 84521.1 copies/μL. While no false-positive results were obtained by any of these tests (specificity: 100% [95% CI, 88.9%-100%]), sensitivity of the nine tests ranged from 68.2% [95% CI, 45.1%-86.1%] to 95.5% [95% CI, 77.2%-99.9%] using LightMix E-gene test as the gold standard. All tests showed positive results for all samples with ≥100 copies/μL. Significant difference of Ct values even among tests amplifying the same genetic region (N1-CDC, N2) was also observed.

conclusionDifference in the diagnostic performance was observed among NAATs approved in Japan. Regarding diagnostic kits for emerging infectious diseases, a system is needed to ensure both rapidity of reagent supply and accuracy of diagnosis. Ct values, which are sometimes regarded as a marker of infectivity, are not interchangeable when obtained by different assays.

Indexed as

CalibrationCoronavirus Envelope ProteinsCOVID-19 Nucleic Acid TestingHumansNucleic Acid Amplification TechniquesPolymerase Chain ReactionSensitivity and SpecificityCoronavirus Envelope Proteinsenvelope protein, SARS-CoV-2

Identifiers

PMID34161355
PMCPMC8221491
OpenAlexW3175002675

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.