Evidence map›Paper›PMID 34159736›Full record

ArticleJournal of applied clinical medical physics2021

Image quality improvement with deep learning-based reconstruction on abdominal ultrahigh-resolution CT: A phantom study.

Takashi Shirasaka, Tsukasa Kojima, Yoshinori Funama, Yuki Sakai, Masatoshi Kondo, Ryoji Mikayama, Hiroshi Hamasaki, Toyoyuki Kato, Yasuhiro Ushijima, Yoshiki Asayama and 1 more

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Takashi ShirasakaDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
Tsukasa KojimaDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
Yoshinori FunamaDepartment of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan.
Yuki SakaiDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
Masatoshi KondoDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
Ryoji MikayamaDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
Hiroshi HamasakiDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
Toyoyuki KatoDivision of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
Yasuhiro UshijimaDepartment of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Yoshiki AsayamaDepartment of Advanced Imaging and Interventional Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Akihiro NishieDepartment of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn an ultrahigh-resolution CT (U-HRCT), deep learning-based reconstruction (DLR) is expected to drastically reduce image noise without degrading spatial resolution. We assessed a new algorithm's effect on image quality at different radiation doses assuming an abdominal CT protocol.

methodsFor the normal-sized abdominal models, a Catphan 600 was scanned by U-HRCT with 100%, 50%, and 25% radiation doses. In all acquisitions, DLR was compared to model-based iterative reconstruction (MBIR), filtered back projection (FBP), and hybrid iterative reconstruction (HIR). For the quantitative assessment, we compared image noise, which was defined as the standard deviation of the CT number, and spatial resolution among all reconstruction algorithms.

resultsDeep learning-based reconstruction yielded lower image noise than FBP and HIR at each radiation dose. DLR yielded higher image noise than MBIR at the 100% and 50% radiation doses (100%, 50%, DLR: 15.4, 16.9 vs MBIR: 10.2, 15.6 Hounsfield units: HU). However, at the 25% radiation dose, the image noise in DLR was lower than that in MBIR (16.7 vs. 26.6 HU). The spatial frequency at 10% of the modulation transfer function (MTF) in DLR was 1.0 cycles/mm, slightly lower than that in MBIR (1.05 cycles/mm) at the 100% radiation dose. Even when the radiation dose decreased, the spatial frequency at 10% of the MTF of DLR did not change significantly (50% and 25% doses, 0.98 and 0.99 cycles/mm, respectively).

conclusionDeep learning-based reconstruction performs more consistently at decreasing dose in abdominal ultrahigh-resolution CT compared to all other commercially available reconstruction algorithms evaluated.

Indexed as

Deep LearningAlgorithmsHumansQuality ImprovementRadiation DosageRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray Computeddeep learning-based reconstructionultrahigh-resolution CT

Identifiers

PMID34159736
PMCPMC8292685

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.