ArticleJournal of applied clinical medical physics2021
Dosimetric impact of using a commercial metal artifact reduction tool in carbon ion therapy in patients with hip prostheses.
Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 8 citations in OpenAlex.
- Optimization of a Q.Clear PET image reconstruction based on bayesian optimization in oncology and neurology applications.Physical and engineering sciences in medicine · 2026Article
- Magnetic Resonance Guided Radical Radiation Therapy for Prostate Cancer in the Presence of Bilateral Hip Prostheses: First Experience With a 1.5 T Magnetic Resonance Linear Accelerator.Advances in radiation oncology · 2026Article
- Commissioning of a commercial treatment planning system for scanned carbon-ion radiotherapy.Journal of applied clinical medical physics · 2025Article
- Feasibility of dose calculation for treatment plans using electron density maps from a novel dual-layer detector spectral CT simulator.Radiation oncology (London, England) · 2024Article
- Commissioning and Validation of CT Number to SPR Calibration in Carbon Ion Therapy Facility.International journal of particle therapy · 2024Article
- Separation Surgery and Adjuvant Carbon Ion Radiotherapy for a Recurrent Solitary Fibrous Tumor/Hemangiopericytoma: A Case Report.Spine surgery and related research · 2023Article
- Carbon-Ion Radiotherapy Using Metal Artifact Reduction Computed Tomography in a Patient with Prostate Cancer with Bilateral Hip Prostheses: A Case Report.Case reports in oncologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 1 country.
Funding
Abstract
The study investigated the dosimetric impact of an iterative metal artifact reduction (iMAR) tool on carbon ion therapy for pelvic cancer patients with hip prostheses. An anthropomorphic pelvic phantom with unilateral and bilateral hip prostheses was used to simulate pelvic cancer patients with metal implants. The raw data obtained from phantom CT scanning were reconstructed with a regular filtered back projection (FBP) algorithm and then corrected with iMAR. The phantom without hip prosthesis was also scanned and used as a reference ground truth (GT). The CT images of three prostate and four sarcoma patients with unilateral hip prosthesis were also reconstructed by FBP and iMAR algorithm and compared. iMAR algorithm reduced the metal artifacts and the maximum WEPL deviation in phantom images from -19.1 to -0.4 mm. However, the CT numbers cannot be retrieved using iMAR for periprosthetic bone materials, eventually leading to a WEPL deviation of -3.6 mm. The use of iMAR improved large discrepancies in DVHs of PTVs and the gamma index between FBP and GT images but increased the difference in the bladder DVH for bilateral hip prostheses due to newly introduced artifacts. In the patient study, the discrepancies of dose distribution were small on iMAR images when compared with FBP images for most cases, except for two sarcoma cases where gamma analysis failed and dose coverage in 98% of the PTV maximally reduced due to large volume of dark metal artifacts. iMAR reduced the metal artifacts and improved dose distribution accuracy in carbon ion radiotherapy for pelvic cancer. However, the residual and newly introduced artifacts, especially with bilateral hip prostheses, may potentially increase WEPL inaccuracy and dose uncertainty. The use of iMAR has the potential to improve carbon ion treatment planning of pelvic cancer but should be used with caution.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.