Evidence map›Paper›PMID 34159719›Full record

ArticleJournal of applied clinical medical physics2021

Development of a physical geometric phantom for deformable image registration credentialing of radiotherapy centers for a clinical trial.

Noriyuki Kadoya, Siwaporn Sakulsingharoj, Tomas Kron, Adam Yao, Nicholas Hardcastle, Alanah Bergman, Hiroyuki Okamoto, Nobutaka Mukumoto, Yujiro Nakajima, Keiichi Jingu and 1 more

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Noriyuki KadoyaDepartment of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan.
Siwaporn SakulsingharojDepartment of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan.
Tomas KronPhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia.
Adam YaoPhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia.
Nicholas HardcastlePhysical Sciences, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia.
Alanah BergmanDepartment of Medical Physics, BC Cancer Agency, Vancouver, BC, Canada.
Hiroyuki OkamotoDepartment of Medical Physics, National Cancer Center Hospital, Tokyo, Japan.
Nobutaka MukumotoDepartment of Radiation Oncology and Image-Applied Therapy, Kyoto University, Kyoto, Japan.
Yujiro NakajimaDepartment of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan.
Keiichi JinguDepartment of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan.
Mitsuhiro NakamuraDepartment of Radiation Oncology and Image-Applied Therapy, Kyoto University, Kyoto, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to develop a physical geometric phantom for the deformable image registration (DIR) credentialing of radiotherapy centers for a clinical trial and tested the feasibility of the proposed phantom at multiple domestic and international institutions. METHODS AND MATERIALS: The phantom reproduced tumor shrinkage, rectum shape change, and body shrinkage using several physical phantoms with custom inserts. We tested the feasibility of the proposed phantom using 5 DIR patterns at 17 domestic and 2 international institutions (21 datasets). Eight institutions used the MIM software (MIM Software Inc, Cleveland, OH); seven used Velocity (Varian Medical Systems, Palo Alto, CA), and six used RayStation (RaySearch Laboratories, Stockholm, Sweden). The DIR accuracy was evaluated using the Dice similarity coefficient (DSC) and Hausdorff distance (HD).

resultsThe mean and one standard deviation (SD) values (range) of DSC were 0.909 ± 0.088 (0.434-0.984) and 0.909 ± 0.048 (0.726-0.972) for tumor and rectum proxies, respectively. The mean and one SD values (range) of the HD value were 5.02 ± 3.32 (1.53-20.35) and 5.79 ± 3.47 (1.22-21.48) (mm) for the tumor and rectum proxies, respectively. In three patterns evaluating the DIR accuracy within the entire phantom, 61.9% of the data had more than a DSC of 0.8 in both tumor and rectum proxies. In two patterns evaluating the DIR accuracy by focusing on tumor and rectum proxies, all data had more than a DSC of 0.8 in both tumor and rectum proxies.

conclusionsThe wide range of DIR performance highlights the importance of optimizing the DIR process. Thus, the proposed method has considerable potential as an evaluation tool for DIR credentialing and quality assurance.

Indexed as

AlgorithmsImage Processing, Computer-AssistedCredentialingHumansRadiotherapy Planning, Computer-AssistedSwedenTomography, X-Ray Computedadaptive radiotherapycredentialingdeformable image registrationphysical phantomquality assurance

Identifiers

PMID34159719
PMCPMC8292683

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.