Evidence map›Paper›PMID 34156556›Full record

ArticleEuropean radiology2021

Variation of computed tomographic angiography-based fractional flow reserve after transcatheter aortic valve implantation.

Yi Zhang, Tian-Yuan Xiong, Yi-Ming Li, Fang-Yang Huang, Yong Peng, Qiao Li, Jia-Fu Wei, Sen He, Kun-Lin Cao, Yuan Feng and 3 more

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 2 pooled it
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 2 syntheses or guidelines pooled it, 9 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Review
  6. Observational
  7. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 4 institutions in 2 countries.

Yi Zhang *Department of Cardiology, West China Hospital, Sichuan University, #37 Guo Xue Alley, Chengdu, 610041, China.
Tian-Yuan Xiong *Department of Cardiology, West China Hospital, Sichuan University, #37 Guo Xue Alley, Chengdu, 610041, China.
Yi-Ming LiDepartment of Cardiology, West China Hospital, Sichuan University, #37 Guo Xue Alley, Chengdu, 610041, China.
Fang-Yang HuangDepartment of Cardiology, West China Hospital, Sichuan University, #37 Guo Xue Alley, Chengdu, 610041, China.
Yong PengDepartment of Cardiology, West China Hospital, Sichuan University, #37 Guo Xue Alley, Chengdu, 610041, China.
Qiao LiDepartment of Cardiology, West China Hospital, Sichuan University, #37 Guo Xue Alley, Chengdu, 610041, China.
Jia-Fu WeiDepartment of Cardiology, West China Hospital, Sichuan University, #37 Guo Xue Alley, Chengdu, 610041, China.
Sen HeDepartment of Cardiology, West China Hospital, Sichuan University, #37 Guo Xue Alley, Chengdu, 610041, China.
Kun-Lin CaoKeya Medical Technology CO. Ltd, Shenzhen, China.
Yuan FengDepartment of Cardiology, West China Hospital, Sichuan University, #37 Guo Xue Alley, Chengdu, 610041, China.
Bo XuDepartment of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Darren MylotteDepartment of Cardiology, University Hospital Galway, Galway, Ireland.
Mao ChenDepartment of Cardiology, West China Hospital, Sichuan University, #37 Guo Xue Alley, Chengdu, 610041, China. hmaochen@vip.sina.com.
Sichuan University · CNWest China Hospital of Sichuan University · CNChinese Academy of Medical Sciences & Peking Union Medical College · CNUniversity Hospital Galway · IE

Funding

National Natural Science Foundation of China 81970325Science and Technology Support Plan of Sichuan province 2018SZ0172 and 2017JY0330West China Hospital "1·3·5" Discipline of Excellence Project Percutaneous transcatheter aortic valve implantation
6 · The paper itself

Abstract

objectivesWe sought to identify the impact of transcatheter aortic valve implantation (TAVI) on changes of fractional flow reserve computed tomography (FFR

methodsA retrospective analysis was done with CT obtained pre-TAVI, prior to hospital discharge and at 1-year follow-up, which provided imaging sources for the calculation of FFR

resultsA total of 190 patients were enrolled. Patients with pre-procedural FFR

conclusionsTAVI directly brings improvement in FFR KEY POINTS: •The effect of TAVI on coronary hemodynamics might be influenced by different ischemic severity and coronary territories reflected by FFR

Indexed as

Coronary Artery DiseaseCoronary StenosisFractional Flow Reserve, MyocardialTranscatheter Aortic Valve ReplacementComputed Tomography AngiographyCoronary AngiographyCoronary VesselsHemodynamicsHumansPredictive Value of TestsRetrospective StudiesSeverity of Illness IndexTomography, X-Ray ComputedComputed tomographyCoronary artery diseaseFunctional flow reserveTranscatheter aortic valve replacement

Identifiers

PMID34156556
OpenAlexW3175936220

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked